Urea-mediated dissociation alleviate the false-positive Treponema pallidum-specific antibodies detected by ELISA

机译:ELISA检测尿素介导的解离减轻假阳性梅毒螺旋体特异性抗体

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The serological detection of antibodies to Treponema pallidum is essential to the diagnosis of syphilis. However, for the presence of cross-reaction, the specific antibody tests [e.g., enzyme-linked immunosorbent assay (ELISA)] always have false-positive results. In this study, we derived and validated the dissociation of urea in an attempt to alleviate the situation of false-positive antibodies to T. pallidum detected by ELISA. Six serum samples that were false-positive antibodies to T. pallidum detected by ELISA, and 16 control serum samples (8 sera positive for both specific IgG and IgM, and 8 IgG-positive and IgM-negative sera) were collected to select the appropriate dissociated concentration and time of urea. Our goal was to establish improved an ELISA method based on the original detection system of ELISA. The sensitivity of the improved ELISA was evaluated by 275 serum samples with class IgM-positive antibodies to T. pallidum. At 6 mol/L with 10 minutes dissociation of urea, 6 samples with false-positive antibodies to T. pallidum were converted to negative, and compared with true-positive antibodies to T. pallidum. The sensitivity of the improved ELISA was 100% by detecting the class IgM-positive antibodies to T. pallidum in sera of patients with syphilis. Considering the importance at the diagnosis of syphilis, antibodies to T. pallidum in serum samples should be retested by the improved ELISA method to avoid false-positive results.
机译:梅毒螺旋体抗体的血清学检测对于梅毒的诊断至关重要。但是,由于存在交叉反应,特异性抗体检测[例如酶联免疫吸附测定(ELISA)]始终会产生假阳性结果。在这项研究中,我们推导并验证了尿素的解离,以减轻通过ELISA检测到的针对苍白螺旋体的假阳性抗体的情况。通过ELISA检测到6份血清均为抗苍白球菌假阳性抗体的血清样品,以及16份对照血清样品(特异IgG和IgM均为8血清阳性,IgG和IgM阴性均为8血清)以选择合适的解离的尿素浓度和时间。我们的目标是在原始的ELISA检测系统的基础上建立一种改进的ELISA方法。改良的ELISA的灵敏度是通过27​​5份血清样本中具有针对梅毒螺旋体的IgM类阳性抗体来评估的。在尿素解离10分钟的情况下,以6 mol / L的浓度将6个带有抗苍白螺旋体假阳性抗体的样品转化为阴性,并与抗苍白螺旋体的真阳性抗体进行比较。通过检测梅毒患者血清中针对梅毒螺旋体的IgM类阳性抗体,改进的ELISA的敏感性为100%。考虑到在梅毒诊断中的重要性,应通过改良的ELISA方法对血清样本中的梅毒螺旋体抗体进行重新测试,以避免假阳性结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号