首页> 美国卫生研究院文献>other >Surgical Fixation of Atypical Femur Fractures in Bisphosphonate-treated Patients
【2h】

Surgical Fixation of Atypical Femur Fractures in Bisphosphonate-treated Patients

机译:双膦酸盐治疗的患者的非典型股骨骨折的手术固定

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

ObjectiveTo evaluate the outcomes of the surgical fixation of atypical femoral fractures in bisphosphonate-treated patients with an intramedullary device.Materials and methodsThis multicentric study was carried out at the department of orthopedics, Dr. Ruth Phau Civil Hospital and Medicare Hospital, Karachi, Pakistan, between 2013 and 2018. In this retrospective observational study, we reviewed 10 bisphosphonate-treated patients, fixed surgically with an intramedullary nail after presenting with radiologically characteristic atypical femur fractures identified according to the American Society for Bone and Mineral Research criteria. We excluded patients with fractures sustained by high-energy trauma, road traffic accidents, fall from a height, and those associated with underlying malignancy.ResultsA total of 11 atypical femoral fractures in 10 patients were included, all of whom were females with a mean age of 68.6 (range 57-82) years. Out of 11 fractures, 81.8% (n=9) were located in the subtrochanteric region and two were located in the femoral shaft. The mean bisphosphonate use was 58.3 months. All patients were treated with intramedullary devices; an intramedullary interlocking nail in two cases and proximal femoral nail antirotation in nine cases. The mean follow-up duration was 12 months. All fractures were united in an average time of 9.9 months (range 6 - 16 months). Implant failure and/or nonunion were not observed, whereas delayed union was noted in five patients.ConclusionIntramedullary fixation is a reliable method for the treatment of atypical femur fractures in bisphosphonate-treated patients owing to its intramedullary placement. These devices act as an internal splint and can provide much more axial stability, reducing the risk of implant fatigue failure due to a delay in fracture healing from prolonged bisphosphonate use.
机译:目的评估使用双膦酸盐治疗的带髓内器械的非典型股骨骨折的手术固定效果。材料和方法这项多中心研究是在巴基斯坦卡拉奇的Ruth Phau民事医院和Medicare医院的骨科进行的。在2013年至2018年之间。在这项回顾性观察性研究中,我们回顾了10例接受双膦酸盐治疗的患者,这些患者经放射放射学特征性非典型股骨骨折后根据美国骨矿物质研究标准确定了手术方式,并用髓内钉固定。我们排除了因高能外伤,道路交通事故,高处摔倒以及与潜在的恶性肿瘤相关的骨折的患者。结果共纳入10例患者的11例非典型股骨骨折,所有患者均为平均年龄的女性68.6年(范围57-82)。在11处骨折中,有81.8%(n = 9)位于转子下区域,其中2处位于股骨干。双膦酸盐平均使用58.3个月。所有患者均接受了髓内装置治疗;髓内交锁钉2例,股骨近端钉抗旋转9例。平均随访时间为12个月。所有骨折的平均合并时间为9.9个月(范围6-16个月)。没有观察到植入失败和/或骨不连,但有5例患者发现了联合愈合延迟。结论髓内固定是双膦酸盐治疗患者的非典型股骨骨折治疗方法,由于其位于髓内,因此是一种可靠的方法。这些装置充当内部夹板,可以提供更大的轴向稳定性,从而降低了由于长期使用双膦酸盐导致骨折愈合延迟而导致植入物疲劳失败的风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号