Monte Carlo‐based investigation of absorbed‐dose energy dependence of radiochromic films in high energy brachytherapy dosimetry

机译:基于蒙特卡洛的高能近距离放射剂量学中放射性变色膜吸收剂量能量依赖性研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Relative absorbed dose energy response correction, R, for various radiochromic films in water phantom is calculated by the use of the Monte Carlo‐based EGSnrc code system for high energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb. The corrections are calculated along the transverse axis of the sources (1‐15 cm). The radiochromic films investigated are EBT, EBT2 (lot 020609 and lot 031109), RTQA, XRT, XRQA, and HS. For the 60Co source, the value of R is about unity and is independent of distance in the water phantom for films other than XRT and XRQA. The XRT and XRQA films showed distance‐dependent R values for this source (the values of R at 15 cm from the source in water are 1.845 and 2.495 for the films XRT and XRQA, respectively). In the case of 137Cs and 192Ir sources, XRT, XRQA, EBT2 (lot 031109), and HS films showed distant‐dependent R values. The rest of the films showed no energy dependence (HS film showed R values less than unity by about 5%, whereas the other films showed R values higher than unity). In the case of 169Yb source, the EBT film showed no energy dependence and EBT2 film (lot 031109) showed a distance‐independent R value of 1.041. The rest of the films showed distance‐dependent R values (increases with distance for the films other than HS). The solid phantoms PMMA and polystyrene enhance the R values for some films when compared the same in the water phantom.PACS number: 87.53.Jw
机译:对于高能近距离放射治疗源,使用基于Monte Carlo的EGSnrc代码系统来计算水体模中各种放射致变色胶片的相对吸收剂量能量响应校正R,可以通过以下方法计算得出:* xmlns:mml =“ http://www.w3。 org / 1998 / Math / MathML“ id =” nlm-math-1“溢出=” scroll“> 60 Co 137 Cs 192 Ir 169 Yb 。沿光源的横轴(1-15厘米)计算校正值。研究的放射致变色膜为EBT,EBT2(批次020609和批次031109),RTQA,XRT,XRQA和HS。对于 60 Co 源,R的值大约为1,并且与水中幻像中的距离无关XRT和XRQA以外的其他电影。 XRT和XRQA胶片显示了该源的距离相关R值(XRT和XRQA胶片在距源15厘米的水中,R的值分别为1.845和2.495)。对于 137 Cs 192 Ir 来源,XRT,XRQA,EBT2(批次031109)和HS胶片显示了远距离依赖的R值。其余的膜没有能量依赖性(HS膜的R值小于1约1%,而其他膜的R值则大于1)。对于 169 Yb 源,EBT膜显示无能量依赖性,EBT2膜(批次031109)显示与距离无关的R值为1.041。其余的影片显示出与距离有关的R值(除了HS以外,其他影片的距离都会增加)。与水模相比,固态模PMMA和聚苯乙烯提高了某些胶片的R值.PACS数:87.53.Jw

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号