Gafchromic XR‐QA2 film as a complementary dosimeter for hand‐monitoring in CTF‐guided biopsies

机译:Gafchromic XR-QA2胶片作为补充剂量计用于在CTF引导下的活检中进行手动监测

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

Computed tomography fluoroscopy (CTF) is a useful imaging technique to guide biopsies, particularly lung biopsies, but it also has the potential for very high hand exposures, despite use of quick‐check method and needle holders whenever feasible. Therefore, reliable monitoring is crucial to ensure the safe use of CTF. This is a challenge, because ring dosimeters monitor exposure only at the base of one finger, while the fingertips may be exposed to the highly collimated CT beam. In this work we have explored the possibility of using Gafchromic XR‐QA2 self‐developing film as a complementary dosimeter to quantify hand exposure during CTF‐guided biopsies. A glove used in a previous study and designed to contain 11 TLDs was adapted to include Gafchromic strips 7 mm wide, covering the fingers. A total of 22 biopsies were successfully performed wearing this GafTLD glove under sterile gloves, and the IR reported no difficulty or reduction of dexterity while wearing it. Comparison of dose distributions obtained from digitization of the Gafchromic film strips and absolute Hp(0.07) readings from TLDs showed good agreement, despite some positional uncertainty due to relative movement. Per procedure, doses at the base of the ring finger can be as low as 3%–8% of hand dose maximum. Accumulated dose at the base of the ring finger was four times lower than the dose maximum.PACS numbers: 07.57.Kp, 29.40.‐n, 85.25.Pb, 87.57.qp
机译:计算机断层扫描荧光透视(CTF)是一种有用的成像技术,可用于指导活检,尤其是肺活检,但尽管可行,仍使用快速检查方法和持针器,但它也有很高的手暴露潜力。因此,可靠的监视对于确保CTF的安全使用至关重要。这是一个挑战,因为环形剂量计只能在一个手指的根部监视曝光,而指尖可能会在高度准直的CT射线下曝光。在这项工作中,我们探索了使用Gafchromic XR-QA2自显影胶片作为补充剂量计来量化CTF引导的活检过程中手部暴露的可能性。先前研究中使用的设计为包含11个TLD的手套适用于包括7 mm宽的Gafchromic条纹,覆盖手指。在无菌手套下戴好该GafTLD手套,共成功进行了22次活检,并且IR报道戴该手套没有困难或灵活性降低。尽管由于相对运动而存在一些位置不确定性,但是对通过全色薄膜条的数字化获得的剂量分布与来自TLD的绝对Hp(0.07)读数进行的比较显示出很好的一致性。每个程序中,无名指根部的剂量可低至最大手部剂量的3%–8%。无名指根部的累积剂量比最大剂量低四倍.PACS值:07.57.Kp,29.40.-n,85.25.Pb,87.57.qp

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号