Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer

机译:肺癌立体定向放疗中靶标量与影响异质性校正的电子传输效应之间的相关性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Recently, stereotactic body radiotherapy (SBRT) for lung cancer is conducted with heterogeneity-corrected treatment plans, as the correction greatly affects the dose delivery to the lung tumor. In this study, the correlation between the planning target volume (PTV) and the dose delivery is investigated by separation of the heterogeneity correction effects into photon attenuation and electron transport. Under Institutional Review Board exemption status, 74 patients with lung cancer who were treated with SBRT were retrospectively evaluated. All treatment plans were generated using an anisotropic analytical algorithm (AAA) of an Eclipse (Varian Medical Systems, Palo Alto, CA) treatment planning system. Two additional plans were created using the same treatment parameters (monitor units, beam angles and energy): a plan with no heterogeneity correction (NC), and a plan calculated with a pencil beam convolution algorithm (PBC). Compared with NC, AAA and PBC isocenter doses were on average 13.4% and 21.8% higher, respectively. The differences in the isocenter dose and the dose coverage for 95% of the PTV (D95%) between PBC and AAA were correlated logarithmically (ρ = 0.78 and ρ = 0.46, respectively) with PTV. Although D95% calculated with AAA was in general 2.9% larger than that for NC, patients with a small PTV showed a negative ΔD95% for AAA due to the significant effect of electron transport. The PTV volume shows logarithmic correlation with the effects of the lateral electron transport. These findings indicate that the dosimetric metrics and prescription, especially in clinical trials, should be clearly evaluated in the context of target volume characteristics and with proper heterogeneity correction.
机译:近来,针对肺癌的立体定向放射疗法(SBRT)采用异质性校正的治疗计划进行,因为校正极大地影响了向肺肿瘤的剂量传递。在这项研究中,通过将异质性校正效应分离为光子衰减和电子传输,研究了计划目标体积(PTV)与剂量输送之间的相关性。根据机构审查委员会的豁免状态,对74例接受SBRT治疗的肺癌患者进行了回顾性评估。所有治疗计划均使用Eclipse(Varian Medical Systems,Palo Alto,CA)治疗计划系统的各向异性分析算法(AAA)生成。使用相同的处理参数(监视器单位,光束角度和能量)创建了另外两个计划:没有异质性校正(NC)的计划,以及使用铅笔束卷积算法(PBC)计算的计划。与NC相比,AAA和PBC等中心剂量分别平均增加13.4%和21.8%。 PBC和AAA之间95%的PTV(D95%)的等中心剂量和剂量覆盖范围的差异与PTV对数相关(分别为ρ= 0.78和ρ= 0.46)。尽管用AAA计算的D95%通常比NC的大2.9%,但由于电子传输的显着影响,PTV小的患者AAA的ΔD95%为负。 PTV体积显示出与横向电子传输效应的对数关系。这些发现表明,应在目标体积特征和适当的异质性校正的情况下,明确评估剂量学指标和处方,尤其是在临床试验中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号