首页> 美国卫生研究院文献>Veterinary Medicine and Science >Measurement of tear production and intraocular pressure in conscious captive European fallow deer (DAMA dama)
【2h】

Measurement of tear production and intraocular pressure in conscious captive European fallow deer (DAMA dama)

机译:有意识圈养的欧洲小鹿(DAMA dama)的泪液产生和眼压测量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Normal values for intraocular pressure (IOP) and tear production in conscious cervids have not been reported to date. Based on trends in zoological institutions to perform non‐anaesthetized health exams, it is applicable to establish normal values in conscious animals, as anaesthesia and sedation can alter these parameters. The goal of this study was to estimate intraocular pressures using rebound tonometry and measure tear production values in a group of healthy, conscious, European fallow deer utilizing chute restraint. Evaluation of these values with regards to instrumentation and restraint variables will be assessed. Complete ophthalmic examinations, including estimation of IOP with rebound tonometry and measurement of tear production with Schirmer tear tests (STT) were performed on nine conscious European fallow deer (Dama dama) restrained in a chute. Correlations between IOP on the unspecified (P) and the equine (H) settings, as well as IOP and STT differences between left (OS) and right (OD) eyes were evaluated, in addition to assessment of correlations between right and left lateral recumbency on IOP and STT. Tear production measurements were 18.7 ± 5.1 mm min−1 with a 95% confidence interval (CI) range of 16.4–21.1 mm min−1. Intraocular pressure measurements for the P setting were 16.1 ± 4.5 mmHg with a 95% CI range of 14.1–18.2 mmHg, and for the H setting were 21.5 ± 5.1 mmHg with a 95% CI range of 19.1–23.9 mmHg. No statistically significant difference (P > 0.05) was found between OS and OD in any test. Neither left nor right lateral recumbency was found to have a statistically significant effect on IOP or STT. This study represents the first assessment of ophthalmic parameters in conscious fallow deer with rebound tonometry and STT.
机译:迄今为止,尚未报告有意识的子宫颈的眼内压(IOP)和泪液产生的正常值。根据动物学机构进行非麻醉性健康检查的趋势,由于麻醉和镇静可以改变这些参数,因此可用于建立有意识动物的正常值。这项研究的目的是使用回弹眼压计估算眼压,并利用斜槽约束装置测量一组健康,有意识的欧洲小鹿的泪液产生值。将评估有关仪表和约束变量的这些值的评估。完整的眼科检查,包括用回弹眼压计估算眼压,并用Schirmer泪液试验(STT)进行泪液产生测量,这些动物被限制在九只清醒的欧洲小鹿(Dama dama)的斜槽内。除了评估左右侧卧位之间的相关性,还评估了未指定(P)和马(H)设置下的IOP之间的相关性,以及左(OS)和右(OD)眼之间的IOP和STT差异。在IOP和STT上。撕裂生产量为18.7±5.1mmmin -1 ,95%置信区间(CI)范围为16.4-21.1mmmmmin -1 。 P设置的眼压测量值为16.1±4.5 mmHg,95%CI范围为14.1-18.2mmHg,H设置为21.5±5.1 mmHg,95%CI范围为19.1-23.9mmHg。在任何测试中,OS和OD之间均未发现统计学上的显着差异(P> 0.05)。没有发现左右侧卧位对IOP或STT有统计学意义的影响。这项研究代表了使用回弹眼压计和STT对有意识的小鹿的眼科参数的首次评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号