首页> 美国卫生研究院文献>Clinical and Experimental Dental Research >The determination of pH of peri‐implant crevicular fluid around one‐piece and two‐piece dental implants: A pilot study
【2h】

The determination of pH of peri‐implant crevicular fluid around one‐piece and two‐piece dental implants: A pilot study

机译:确定一件式和两件式牙科植入物周围的植入物周围龈沟液的pH:一项先导研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

There are two main groups of screw‐type dental implant designs: one‐piece and two‐piece implants. Although success rates of both of these types of implants are high, none of them avoid complications, of which the most common are peri‐implant mucositis and peri‐implantitis. Current clinical diagnostic parameters are relatively noninvasive and cost‐efficient; however, they are often not sensitive enough and fail to determine the activity of inflammation. The purpose of this study is to determine pH of peri‐implant crevicular fluid (PICF) around one‐piece and two‐piece implants and pH of gingival crevicular fluid (GCF) around healthy teeth and to find out if our suggested method could function accurately for determination of pH of PICF and GCF. Thermo Fisher Scientific™ Orion™ 9863BN glass microelectrode was used to determine pH of PICF around 29 one‐piece (ROOTT, TRATE AG) and 29 two‐piece implants (multiple manufacturers) and pH of GCF around 29 healthy teeth. pH of PICF around two‐piece implants was more acidic (P < 0.001). Average pH around one‐piece implants was 6.46 and around two‐piece implants was 6.15. Mean pH of GCF was 6.64. pH of PICF in women around two‐piece implants was more alkaline (P < 0.05); no difference was found in control and one‐piece implant groups. There was no statistically significant correlation found between age and pH of PICF and GFC. Design of dental implants has an impact on pH of PICF. Glass microelectrode is an appropriate tool for accurate determination of pH in PICF.
机译:螺钉型牙种植体设计主要分为两类:一件式和两件式种植体。尽管这两种类型的植入物的成功率都很高,但它们都不能避免并发症,其中最常见的是植入物周围粘膜炎和植入物周围炎。当前的临床诊断参数相对无创且具有成本效益。但是,它们通常不够灵敏,无法确定炎症活动。这项研究的目的是确定一件式和两件式种植体周围的种植体周围胎液(PICF)的pH值以及健康牙齿周围的龈沟液(GCF)的pH值,并找出我们建议的方法是否可以准确发挥作用用于测定PICF和GCF的pH。 Thermo Fisher Scientific™Orion™9863BN玻璃微电极用于测定29颗单件(ROOTT,TRATE AG)和29颗两件式植入物(多家制造商)附近的PICF的pH值以及29颗健康牙齿周围的GCF的pH值。两件式植入物周围的PICF的pH值更酸性(P <0.001)。一件式植入物周围的平均pH为6.46,两件式植入物周围的平均pH为6.15。 GCF的平均pH为6.64。两件式植入物周围的女性中PICF的pH值更碱性(P <0.05);对照组和单件植入物组无差异。 PICF和GFC的年龄与pH值之间没有统计学上的显着相关性。牙植入物的设计对PICF的pH有影响。玻璃微电极是准确测定PICF中pH值的合适工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号