Conversion Coefficients for Proton Beams using Standing and Sitting Male Hybrid Computational Phantom Calculated in Idealized Irradiation Geometries

机译:使用理想化辐射几何中计算的站立和坐立混合动力幻影对质子束的转换系数

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of this study was the calculation of conversion coefficients for absorbed doses per fluence (DT/Φ) using the sitting and standing male hybrid phantom (UFH/NCI) exposure to monoenergetic protons with energy ranging from 2 MeV to 10 GeV. Sex-averaged effective dose per fluence (E/Φ) using the results of DT/Φ for the male and female hybrid phantom in standing and sitting postures were also calculated. Results of E/Φ of UFH/NCI standing phantom were also compared with tabulated effective dose conversion coefficients provided in ICRP publication 116. To develop an exposure scenario implementing the male UFH/NCI phantom in sitting and standing postures was used the radiation transport code MCNPX. Whole-body irradiations were performed using the recommended irradiation geometries by ICRP publication 116 antero-posterior (AP), postero-anterior (PA), right and left lateral, rotational (ROT) and isotropic (ISO). In most organs, the conversion coefficients DT/Φ were similar for both postures. However, relative differences were significant for organs located in the lower abdominal region, such as prostate, testes and urinary bladder, especially in the AP geometry. Results of effective dose conversion coefficients were 18% higher in the standing posture of the UFH/NCI phantom, especially below 100 MeV in AP and PA. In lateral geometry, the conversion coefficients values below 20 MeV were 16% higher in the sitting posture. In ROT geometry, the differences were below 10%, for almost all energies. In ISO geometry, the differences in E/Φ were negligible. The results of E/Φ of UFH/NCI phantom were in general below the results of the conversion coefficients provided in ICRP publication 116.
机译:这项研究的目的是使用坐在和站立的男性混合体模(UFH / NCI)暴露于能量为2 MeV到10 GeV的单能质子,计算每通量吸收剂量(DT /Φ)的转换系数。还使用男女混合体模在站立和坐姿中的DT /Φ结果,计算了每通量的平均性别有效剂量(E /Φ)。还比较了UFH / NCI站立体模的E /Φ结果和ICRP出版物116中提供的列表有效剂量转换系数。为了建立在坐姿和站立姿势下实施男性UFH / NCI体模的暴露方案,使用了辐射传输代码MCNPX 。使用ICRP出版物116前后(AP),后前(PA),左右和外侧,旋转(ROT)和各向同性(ISO)的推荐照射几何结构进行全身照射。在大多数器官中,两种姿势的转换系数DT /Φ相似。然而,对于位于下腹部区域的器官,例如前列腺,睾丸和膀胱,相对差异是显着的,尤其是在AP几何形状中。 UFH / NCI体模的站立姿势有效剂量转换系数的结果高出18%,尤其是在AP和PA中低于100 MeV的情况下。在横向几何形状中,在坐姿下,低于20 MeV的转换系数值高16%。在ROT几何中,几乎所有能量的差异都低于10%。在ISO几何中,E /Φ的差异可忽略不计。 UFH / NCI体模的E /Φ结果通常低于ICRP出版物116中提供的转换系数结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号