首页> 美国卫生研究院文献>Scientific Reports >Pulse Rate Measurement During Sleep Using Wearable Sensors and its Correlation with the Menstrual Cycle Phases A Prospective Observational Study
【2h】

Pulse Rate Measurement During Sleep Using Wearable Sensors and its Correlation with the Menstrual Cycle Phases A Prospective Observational Study

机译:使用可穿戴式传感器的睡眠期间脉搏率测量及其与月经周期阶段的相关性一项前瞻性观察性研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

An affordable, user-friendly fertility-monitoring tool remains an unmet need. We examine in this study the correlation between pulse rate (PR) and the menstrual phases using wrist-worn PR sensors. 91 healthy, non-pregnant women, between 22–42 years old, were recruited for a prospective-observational clinical trial. Participants measured PR during sleep using wrist-worn bracelets with photoplethysmographic sensors. Ovulation day was estimated with “Clearblue Digital-Ovulation-urine test”. Potential behavioral and nutritional confounders were collected daily. 274 ovulatory cycles were recorded from 91 eligible women, with a mean cycle length of 27.3 days (±2.7). We observed a significant increase in PR during the fertile window compared to the menstrual phase (2.1 beat-per-minute, p < 0.01). Moreover, PR during the mid-luteal phase was also significantly elevated compared to the fertile window (1.8 beat-per-minute, p < 0.01), and the menstrual phase (3.8 beat-per-minute, p < 0.01). PR increase in the ovulatory and mid-luteal phase was robust to adjustment for the collected confounders. There is a significant increase of the fertile-window PR (collected during sleep) compared to the menstrual phase. The aforementioned association was robust to the inter- and intra-person variability of menstrual-cycle length, behavioral, and nutritional profiles. Hence, PR monitoring using wearable sensors could be used as one parameter within a multi-parameter fertility awareness-based method.
机译:负担得起的,用户友好的生育率监控工具仍未得到满足。我们在这项研究中检查了使用腕戴式PR传感器的脉搏率(PR)与月经期之间的相关性。招募了91名22至42岁之间的健康,未怀孕的妇女进行前瞻性观察临床试验。参与者使用带光电容积描记器的腕戴式手镯测量睡眠期间的PR。排卵日用“ Clearblue Digital-Ovulation-urine test”评估。每天收集潜在的行为和营养混杂因素。从91名合格妇女中记录了274个排卵周期,平均周期长度为27.3天(±2.7)。与月经期相比,我们在生育期观察到PR的显着增加(每分钟2.1次,p <0.01)。此外,与可育期窗(每分钟1.8拍,p <0.01)和月经期(每分钟3.8拍,p <0.01)相比,黄体中期的PR也显着升高。排卵期和黄体中期的PR升高对于调整所收集的混杂因素是有力的。与月经期相比,可孕窗口PR(在睡眠期间收集)显着增加。前面提到的关联对月经周期长度,行为和营养状况的人际和人际变异具有鲁棒性。因此,使用可穿戴传感器的PR监测可以用作基于多参数生育意识的方法中的一个参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号