首页> 美国卫生研究院文献>Scientific Reports >Retrospective Analysis of Structural Disease Progression in Retinitis Pigmentosa Utilizing Multimodal Imaging
【2h】

Retrospective Analysis of Structural Disease Progression in Retinitis Pigmentosa Utilizing Multimodal Imaging

机译:利用多模态成像回顾性色素性视网膜炎结构性疾病进展

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In this report, we assess the natural progression rate of retinitis pigmentosa (RP) over an average of three years using spectral-domain optical coherence tomography (SD-OCT) and short wavelength fundus autofluorescence (SW-AF). Measurement of the ellipsoid zone (EZ) line width and hyperautofluorescent ring diameters was performed in 81 patients with RP in a retrospective, longitudinal fashion. Rate of structural disease progression, symmetry between eyes, and test-retest variability were quantified. We observed on average, EZ-line widths decreased by 140 µm (5.2%, p < 0.001) per year, and average horizontal and vertical hyperautofluorescent ring diameters decreased by 149 µm (3.6%, p < 0.001) and 120 µm (3.9%, p < 0.001) per year, respectively. The 95th percentile of this cohort had differences in progression slopes between eyes that were less than 154 µm, 118 µm, and 132 µm for EZ-line width and horizontal and vertical ring diameters, respectively. For all measures except horizontal ring diameter, progression rates were significantly slower at end-stage disease. From our data, we observed a statistically significant progression rate in EZ line width and SW-AF ring diameters over time, verifying the utility of these measurements for disease monitoring purposes. Additionally, calculated differences in progression slopes between eyes may prove useful for investigators evaluating the efficacy of unilateral treatments for RP in clinical trials.
机译:在本报告中,我们使用光谱域光学相干断层扫描(SD-OCT)和短波长眼底自发荧光(SW-AF)评估了平均三年色素性视网膜炎(RP)的自然进展速度。以回顾性,纵向的方式对81例RP患者进行了椭球区(EZ)线宽和超自发荧光环直径的测量。定量了结构性疾病进展的速度,两眼之间的对称性和重测变异性。我们平均观察到,EZ线宽度每年减少140 µm(5.2%,p <0.001),水平和垂直超自动荧光环的平均直径分别减少149 µm(3.6%,p <0.001)和120 µm(3.9%) ,p <0.001)每年。该队列的第95个百分数在EZ线宽度和水平和垂直环直径分别小于154μm,118μm和132μm的眼睛之间具有不同的前进斜率差异。对于除水平环直径以外的所有测量,末期疾病的进展速度明显减慢。根据我们的数据,我们观察到EZ线宽和SW-AF环直径随时间的变化具有统计学上的显着提高,证明了这些测量在疾病监测中的实用性。此外,计算得出的两眼之间的进展斜率差异可能有助于研究人员评估临床试验中单侧RP治疗的疗效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号