首页> 美国卫生研究院文献>Oncology Letters >Microplate magnetic chemiluminescence immunoassay for detecting urinary survivin in bladder cancer
【2h】

Microplate magnetic chemiluminescence immunoassay for detecting urinary survivin in bladder cancer

机译:微孔板磁化学发光免疫法检测膀胱癌中尿survivin

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Survivin is a tumor marker for bladder cancer; however the role of urinary survivin levels has not been fully elucidated due to the limitations of current detection methods. Based on two survivin-specific monoclonal antibodies (McAbs) already confirmed through enzyme linked immunosorbent assays, the present study aimed to establish a microplate magnetic chemiluminescence immunoassay (CLIA) for the detection of urinary survivin levels and evaluate its application for the diagnosis of patients with bladder cancer. Horseradish peroxidase and biotin conjugates were used to label two different anti-survivin McAbs, respectively. The labeled antibodies combined with survivin to form a sandwiched immune complex. The streptavidin magnetic particles (MPs) served as the solid phase and the separator. The relevant parameters involved in the immunoassay, including the immunoassay reagents used and the physicochemical parameters were optimized. Then, urine samples from 130 patients with bladder cancer and 113 healthy controls were detected, and analyzed using the established method. The method was linear to 1,000 ng/ml survivin with a detection limit of 0.83 ng/ml. The intra- and inter-assay coefficients of variation were <8, and <11%, respectively. The concentration of diluted survivin and the dilution ratios gave a linear correlation of 0.9989. The results demonstrated that the urinary survivin levels in patients with bladder cancer were significantly higher (P<0.001) compared with that in healthy controls. At a survivin concentration of 2.0884 ng/ml, the sensitivity and specificity were 86.9 and 61.9%, respectively. Furthermore, the urinary survivin levels were positively correlated with metastatic stage, histological stage and recurrence (P<0.01). In conclusion, the present study preliminarily proposed a microplate magnetic CLIA for survivin detection and further evaluated the value of urinary survivin as a diagnostic marker for bladder cancer.
机译:Survivin是膀胱癌的肿瘤标志物;然而,由于目前检测方法的局限性,尿中survivin水平的作用尚未完全阐明。基于已经通过酶联免疫吸附测定法确认的两种存活蛋白特异性单克隆抗体(McAbs),本研究旨在建立微孔板磁化学发光免疫测定法(CLIA),用于检测尿液存活蛋白水平,并评估其在诊断患有尿毒症的患者中的应用膀胱癌。辣根过氧化物酶和生物素结合物分别用于标记两种不同的抗生存素单克隆抗体。标记的抗体与生存素结合形成夹心的免疫复合物。链霉亲和素磁性颗粒(MPs)用作固相和分离器。优化了免疫测定中涉及的相关参数,包括使用的免疫测定试剂和理化参数。然后,从130名膀胱癌患者和113名健康对照中检测尿液样本,并使用既定方法进行分析。该方法与1,000 ng / ml survivin呈线性关系,检出限为0.83 ng / ml。批内和批间变异系数分别<8%和<11%。稀释的存活蛋白的浓度和稀释比的线性相关性为0.9989。结果表明,与健康对照组相比,膀胱癌患者的尿生存素水平显着更高(P <0.001)。在survivin浓度为2.0884 ng / ml时,敏感性和特异性分别为86.9%和61.9%。此外,尿中survivin水平与转移阶段,组织学阶段和复发呈正相关(P <0.01)。总之,本研究初步提出了一种用于检测survivin的微孔板磁性CLIA,并进一步评估了尿survivin作为膀胱癌诊断标志物的价值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号