摘要

>Purpose: This article presents a computer-aided diagnosis technique for improving the accuracy of the early diagnosis of Alzheimer’s disease (AD). Two hundred and ten 18F-FDG PET images from the ADNI initiative [52 normal controls (NC), 114 mild cognitive impairment (MCI), and 53 AD subjects] are studied.>Methods: The proposed methodology is based on the selection of voxels of interest using the t-test and a posterior reduction of the feature dimension using factor analysis. Factor loadings are used as features for three different classifiers: Two multivariate Gaussian mixture model, with linear and quadratic discriminant function, and a support vector machine with linear kernel.>Results: An accuracy rate up to 95% when NC and AD are considered and an accuracy rate up to 88% and 86% for NC-MCI and NC-MCI,AD, respectively, are obtained using SVM with linear kernel.>Conclusions: Results are compared to the voxel-as-features and a PCA- based approach and the proposed methodology achieves better classification performance.
机译:>目的:本文介绍了一种计算机辅助诊断技术,可提高阿尔茨海默氏病(AD)早期诊断的准确性。研究了来自ADNI计划的121张 18 F-FDG PET图像[52名正常对照(NC),114名轻度认知障碍(MCI)和53名AD受试者]。>方法: 所提出的方法基于使用t检验选择感兴趣的体素,并使用因子分析对特征尺寸进行后验缩减。因子负荷被用作三个不同分类器的特征:两个具有线性和二次判别函数的多元高斯混合模型,以及一个具有线性核的支持向量机。>结果:当考虑使用NC和AD,使用带有线性核的SVM分别获得NC-MCI和NC-MCI,AD的准确率分别达到88%和86%。>结论:结果与基于体素的功能和基于PCA的方法以及所提出的方法可实现更好的分类性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号