Fresnel zone plates (FZPs) recently showed significant improvement by focusing soft X-rays down to ∼10 nm. In contrast to soft X-rays, generally a very high aspect ratio FZP is needed for efficient focusing of hard X-rays. Therefore, FZPs had limited success in the hard X-ray range owing to difficulties of manufacturing high-aspect-ratio zone plates using conventional techniques. Here, employing a method of fabrication based on atomic layer deposition (ALD) and focused ion beam (FIB) milling, FZPs with very high aspect ratios were prepared. Such multilayer FZPs with outermost zone widths of 10 and 35 nm and aspect ratios of up to 243 were tested for their focusing properties at 8 keV and shown to focus hard X-rays efficiently. This success was enabled by the outstanding layer quality thanks to ALD. Via the use of FIB for slicing the multilayer structures, desired aspect ratios could be obtained by precisely controlling the thickness. Experimental diffraction efficiencies of multilayer FZPs fabricated via this combination reached up to 15.58% at 8 keV. In addition, scanning transmission X-ray microscopy experiments at 1.5 keV were carried out using one of the multilayer FZPs and resolved a 60 nm feature size. Finally, the prospective of different material combinations with various outermost zone widths at 8 and 17 keV is discussed in the light of the coupled wave theory and the thin-grating approximation. Al2O3/Ir is outlined as a promising future material candidate for extremely high resolution with a theoretical efficiency of more than 20% for as small an outermost zone width as 10 nm at 17 keV.
机译:菲涅耳波带片(FZPs)最近通过将软X射线聚焦至约10 nm而显示出显着改善。与软X射线相反,通常需要非常高的纵横比FZP以有效地聚焦硬X射线。因此,由于难以使用常规技术制造高纵横比的带状板,FZP在硬X射线范围内的成功有限。在此,采用基于原子层沉积(ALD)和聚焦离子束(FIB)铣削的制造方法,制备了具有非常高纵横比的FZP。测试了这种最外层区域宽度为10和35 nm且纵横比最大为243的多层FZP,其在8 keV的聚焦特性,并显示出可有效聚焦硬X射线。借助ALD,出色的图层质量确保了这一成功。通过使用FIB切片多层结构,可以通过精确控制厚度来获得所需的纵横比。通过这种组合制造的多层FZP的实验衍射效率在8 keV时达到了15.58%。此外,使用多层FZP之一在1.5 keV下进行了扫描透射X射线显微镜实验,分辨出60 nm的特征尺寸。最后,根据耦合波理论和薄光栅近似,讨论了在8和17 keV处具有不​​同最外层宽度的不同材料组合的前景。 Al2O3 / Ir被概述为极有希望的未来材料,它具有极高的分辨率,在17 forkeV的最小外层宽度只有10 widthnm的情况下,理论效率超过20%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号