首页> 美国卫生研究院文献>The Journal of Bone and Joint Surgery. American Volume >Cemented Total Hip Replacement Cable Debris and Acetabular Construct Durability
【2h】

Cemented Total Hip Replacement Cable Debris and Acetabular Construct Durability

机译:固定的全髋关节置换电缆碎屑和髋臼结构耐用性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used.>Methods: Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs.>Results: The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% ± 9% and 83% ± 7% for the cable and wire groups, respectively, at twenty years (p = 0.03).>Conclusions: Because cable trochanteric attachment led to significantly greater polyethylene wear, osteolysis, acetabular loosening, and acetabular revision, presumably due to third-body metallic debris generation in this cemented total hip replacement construct, surgeons should be aware of the deleterious effects of third-body debris and avoid the use of potential debris generators in the total hip arthroplasty construct. If cable is used and fretting is recognized, especially with intra-articular migration of metallic material or nonunion of the greater trochanter, consideration should be given to cable removal.>Level of Evidence: Therapeutic Level III. See Instructions to Authors for a complete description of levels of evidence.
机译:>背景:第三者的穿着会引起聚乙烯磨损,溶骨作用和部件松动,从而对全髋关节置换术的结果产生不利影响。我们假设,与使用不锈钢丝的髋关节相比,使用钴铬缆线重新固定截骨大转子的髋关节中,金属碎屑的产生和迁移会更大。>方法: 在1981年6月至1983年12月之间,连续进行196次全髋关节置换术,其中使用了爱荷华州的茎和钛支持的髋臼假体,并进行了钴铬合金的粗大转子再植。在进行了19到20年的随访之后,对患者进行了以下评估:头部渗透到聚乙烯中的深度(作为磨损的替代物),溶骨,松弛和翻修的必要性。将结果与同一位外科医生于1984年1月至1985年12月使用相同的组件和相同的外科手术技术但使用不锈钢丝转子粗隆再植进行的一系列304次全髋关节置换术的结果进行了比较。两组的随访时间为十九至二十年。所有活着的患者(电缆组为59髋,电线组为92髋)均至少有10年的随访X线照片。>结果:聚乙烯的磨损率为0.101 mm /年电缆组为0.082 mm / yr(电线组)(p = 0.039)。对于活着的患者,电缆组由于无菌性松动而引起的髋臼组件翻修率为37.3%(22髋),而线材组为20.7%(19髋)(p = 0.025)。电缆组的髋臼骨溶解率是44%(26髋),而线材组的髋臼骨溶解率是26%(24髋)(p = 0.022)。 Kaplan-Meier分析(以无菌松动为终点,髋臼假体进行了修订)表明电缆和电线组在20年时的存活率分别为73.7%±9%和83%±7%(p = 0.03) 。>结论::由于滑行股骨转子附着导致聚乙烯磨损,溶骨,髋臼松动和髋臼翻修明显增加,大概是由于在这种骨水泥全髋关节置换结构中产生了第三体金属碎屑,因此外科医生应该意识到第三体碎片的有害影响,并避免在整个髋关节置换结构中使用潜在的碎片生成器。如果使用电缆并且可以识别微动,特别是在金属材料的关节内迁移或大转子的骨不连合时,则应考虑去除电缆。>证据级别:治疗级别III。有关证据水平的完整说明,请参见《作者须知》。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号