A Comparison between Manual and Automated Evaluations of Tissue Microarray Patterns of Protein Expression

机译:手动和自动评估组织微阵列蛋白表达模式的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Tissue microarray technology enables us to evaluate the pattern of protein expression in large numbers of samples. However, manual data acquisition and analysis still represent a challenge because they are subjective and time-consuming. Automated analysis may thus increase the speed and reproducibility of evaluation. However, the reliability of automated analysis systems should be independently evaluated. Herein, the expression of phosphorylated AKT and mTOR was determined by ScanScope XT (Aperio; Vista, CA) and ACIS III (Dako; Glostrup, Denmark) and compared with the manual analysis by two observers. The percentage of labeled pixels or nuclei analysis had a good correlation between human observers and automated systems (κ = 0.855 and 0.879 for ScanScope vs. observers and κ = 0.765 and 0.793 for ACIS III vs. observers). The intensity of labeling determined by ScanScope was also correlated with that found by the human observers (correlation index of 0.946 and 0.851 for pAKT and 0.851 and 0.875 for pmTOR). However, the correlation between ACIS III and human observation varied for labeling intensity and was considered poor in some cases (correlation index of 0.718 and 0.680 for pAKT and 0.223 and 0.225 for pmTOR). Thus, the percentage of positive pixels or nuclei determination was satisfactorily performed by both systems; however, labeling intensity was better identified by ScanScope XT.
机译:组织微阵列技术使我们能够评估大量样品中蛋白质表达的模式。但是,手动数据采集和分析仍然是一个挑战,因为它们既主观又费时。因此,自动分析可以提高评估的速度和可重复性。但是,自动化分析系统的可靠性应独立评估。在此,磷酸化的AKT和mTOR的表达由ScanScope XT(Aperio; Vista,CA)和ACIS III(Dako; Glostrup,丹麦)确定,并与两名观察员的手动分析进行比较。标记像素或原子核分析的百分比在人类观察者和自动化系统之间具有良好的相关性(ScanScope与观察者的κ= 0.855和0.879,ACIS III与观察者的κ= 0.765和0.793)。 ScanScope确定的标记强度也与人类观察者发现的强度相关(pAKT的相关指数为0.946和0.851,pmTOR的相关指数为0.851和0.875)。但是,ACIS III和人类观察结果之间的相关性因标记强度而异,并且在某些情况下被认为较弱(pAKT的相关指数为0.718和0.680,pmTOR的相关指数为0.223和0.225)。因此,两个系统均令人满意地执行了正像素百分比或原子核确定;但是,ScanScope XT可以更好地识别标签强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号