首页> 美国卫生研究院文献>The Journal of the Acoustical Society of America >Simulations of the effect of unlinked cochlear-implant automatic gain control and head movement on interaural level differences
【2h】

Simulations of the effect of unlinked cochlear-implant automatic gain control and head movement on interaural level differences

机译:模拟未连接的人工耳蜗自动增益控制和头部运动对耳间水平差异的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This study simulated the effect of unlinked automatic gain control (AGC) and head movement on the output levels and resulting ILDs produced by bilateral CI processors. The angular extent and velocity of the head movements were varied in order to observe the interaction between unlinked AGC and head movement. Static, broadband input ILDs were greatly reduced by the high-ratio, slow time-constant AGC used. The size of head-movement-induced dynamic ILDs depended more on the velocity and angular extent of the head movement than on the angular position of the source. The profiles of the dynamic, broadband output ILDs were very different from the dynamic, broadband input ILD profiles. Short-duration, high-velocity head movements resulted in dynamic output ILDs that continued to change after head movement had stopped. Analysis of narrowband, single-channel ILDs showed that static output ILDs were reduced across all frequencies, producing low-frequency ILDs of the opposite sign to the high-frequency ILDs. During head movements, low-frequency and high-frequency ILDs changed with opposite sign. The results showed that the ILDs presented to bilateral CI listeners during head turns were highly distorted by the interaction of the bilateral, unlinked AGC and the level changes induced by head movement.
机译:这项研究模拟了无关联自动增益控制(AGC)和磁头移动对双边CI处理器产生的输出水平和最终ILD的影响。改变头部运动的角度范围和速度,以便观察未关联的AGC与头部运动之间的相互作用。静态,宽带输入ILD通过使用比例高,时间常数慢的AGC大大降低了。磁头移动引起的动态ILD的大小更多地取决于磁头移动的速度和角度范围,而不是源的角度位置。动态宽带输出ILD的配置文件与动态宽带输入ILD的配置文件有很大不同。短时间的高速头部运动导致动态输出ILD在头部运动停止后继续变化。对窄带单通道ILD的分析表明,静态输出ILD在所有频率上都减小了,从而产生了与高频ILD符号相反的低频ILD。头部运动期间,低频和高频ILD的符号相反。结果表明,在头转弯时呈现给双边CI听众的ILD受双边,未关联的AGC的相互作用和头移动引起的水平变化的影响而严重失真。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号