This method was designed for sampling select quaternary ammonium (quat) compounds in air or on surfaces followed by analysis using ultraperformance liquid chromatography tandem mass spectrometry. Target quats were benzethonium chloride, didecyldimethylammonium bromide, benzyldimethyldodecylammonium chloride, benzyldimethyltetradecylammonium chloride, and benzyldimethylhexadecylammonium chloride. For air sampling, polytetrafluoroethylene (PTFE) filters are recommended for 15-min to 24-hour sampling. For surface sampling, Pro-wipe® 880 (PW) media was chosen. Samples were extracted in 60:40 acetonitrile:0.1% formic acid for 1 hour on an orbital shaker. Method detection limits range from 0.3 to 2 ng/ml depending on media and analyte. Matrix effects of media are minimized through the use of multiple reaction monitoring versus selected ion recording. Upper confidence limits on accuracy meet the National Institute for Occupational Safety and Health 25% criterion for PTFE and PW media for all analytes. Using PTFE and PW analyzed with multiple reaction monitoring, the method quantifies levels among the different quats compounds with high precision (<10% relative standard deviation) and low bias (<11%). The method is sensitive enough with very low method detection limits to capture quats on air sampling filters with only a 15-min sample duration with a maximum assessed storage time of 103 days before sample extraction. This method will support future exposure assessment and quantitative epidemiologic studies to explore exposure–response relationships and establish levels of quats exposures associated with adverse health effects.
机译:该方法旨在对空气中或表面上的选定季铵(季铵盐)化合物进行采样,然后使用超高效液相色谱串联质谱法进行分析。目标季铵盐是苄索氯铵,二癸基二甲基溴化铵,苄基二甲基十二烷基氯化铵,苄基二甲基十四烷基氯化铵和苄基二甲基十六烷基氯化铵。对于空气采样,建议使用聚四氟乙烯(PTFE)过滤器进行15分钟到24小时的采样。对于表面采样,选择了Pro-wipe ® 880(PW)介质。将样品在60:40乙腈:0.1%甲酸中在定轨振荡器上萃取1小时。方法检测极限范围为0.3到2 ng / ml,具体取决于介质和分析物。与选择的离子记录相比,通过使用多反应监测可以最大程度地降低介质的基质效应。准确性的置信上限符合美国国家职业安全与健康研究所对所有分析物的PTFE和PW介质的25%标准。通过对PTFE和PW进行多反应监测分析,该方法以高精度(相对标准偏差<10%)和低偏差(<11%)对不同季铵化合物之间的含量进行定量。该方法灵敏度高,方法检出限非常低,仅用15分钟的采样时间即可捕获空气采样过滤器上的季铵盐,而提取样品之前的最大评估存储时间为103天。该方法将支持未来的暴露评估和定量流行病学研究,以探索暴露与反应的关系,并建立与不良健康影响相关的四价季暴露水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号