首页> 美国卫生研究院文献>American Journal of Physiology - Renal Physiology >Estimating postvoid residual volume without measuring residual bladder volume during serial cystometrograms
【2h】

Estimating postvoid residual volume without measuring residual bladder volume during serial cystometrograms

机译:估计连续尿量测图期间的空后残留量而无需测量残留膀胱量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The postvoid residual volume (PVR) is a common urodynamic parameter used to quantify the severity of lower urinary tract dysfunction. However, the serial cystometrograms that are typically used to assess bladder function in animal models make measuring PVR very difficult. Current approaches are to either remove PVR after each void to measure it, which is disruptive to the bladder, or to neglect the unknown contribution to PVR from ureter flow, which results in inaccurate estimates. We propose a procedure to estimate PVR during a serial cystometrogram that requires only a single measurement, rather than measuring after each void. Moreover, this measurement can occur at the end of the experiment such that it does not affect the bladder during data collection. We mathematically express PVR for all voids during a serial cystometrogram using a linear recurrence equation and use this equation to build an estimation procedure for PVR. Using in vivo measurements in urethane anesthetized rats and computer simulations we show that the estimation procedure is at least as accurate in determining PVR as the traditional method of measuring PVR after each void. Furthermore, we demonstrate the adverse effects of repeated PVR measurements in a common animal model of cystitis. Using the proposed procedure can increase the efficiency and accuracy of determining PVR for a serial cystometrogram and is less disruptive to the system under study. This, in turn, allows the calculation of other urodynamic parameters that are critical for research studies, including voiding efficiency and bladder capacity.
机译:无效后残余容积(PVR)是常见的尿动力学参数,用于量化下尿路功能障碍的严重程度。但是,通常用于评估动物模型中膀胱功能的连续膀胱测压图使测量PVR非常困难。当前的方法是在每个空隙后去除PVR以对其进行测量,这会破坏膀胱,或者忽略输尿管流量对PVR的未知贡献,这会导致估算不准确。我们提出了一种在连续膀胱测压图中估计PVR的过程,该过程仅需进行一次测量即可,而无需在每个空隙后进行测量。此外,该测量可以在实验结束时进行,以使其在数据收集期间不会影响膀胱。我们使用线性递归方程在串行膀胱造影图中数学表达所有空隙的PVR,并使用该方程建立PVR的估算程序。使用在氨基甲酸乙酯麻醉的大鼠中进行的体内测量和计算机模拟,我们显示,确定PVR的估算程序至少与测量每个空隙后PVR的传统方法一样准确。此外,我们证明了在常见的膀胱炎动物模型中重复进行PVR测量的不利影响。使用建议的程序可以提高确定连续膀胱造影图的PVR的效率和准确性,并且对正在研究的系统的干扰较小。反过来,这又可以计算出对研究至关重要的其他尿动力学参数,包括排尿效率和膀胱容量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号