首页> 美国卫生研究院文献>Acta Orthopaedica >Repeated cobalt and chromium ion measurements in patients with large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement
【2h】

Repeated cobalt and chromium ion measurements in patients with large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement

机译:大直径头部金属对金属ReCap-M2A-Magnum全髋关节置换术患者中重复进行钴和铬离子测量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background and purpose — Whole blood (WB) cobalt (Co) and chromium (Cr) ion levels have a major role in the follow-up of metal-on-metal total hip replacement (MoM THR). We investigated, first, if there was a change in WB Co or Cr levels over repeated measurements in patients with ReCap-M2A-Magnum THR, and, second, determined how many patients had WB Co or Cr levels that exceeded the safe upper limits (SUL) in the repeated whole blood metal ion assessment.Patients and methods — A Recap-M2A-Magnum THR was used in 1,329 operations (1,188 patients) at our institution between 2005 and 2012. We identified all patients (n = 319) with unilateral ReCap-M2A-Magnum implants who had undergone at least 2 repeated metal ion measurements with the first blood sample taken mean 5.5 years (1.8–9.3) after surgery and the second taken mean 2 years (0.5–3) after the first.Results — The median WB Co and Cr ion levels decreased in repeated measurements from 1.40 (0.40–63) ppb to 1.10 (0.20–68) ppb and from 1.60 (0.60–13.0) ppb to 1.10 (0.30–19.0) ppb, respectively. 7% of the Co ion values exceeded SUL at the initial measurement, and 7% at the control measurement. The proportion of Cr ion values exceeding the safe upper limit (SUL) decreased during the measurement interval from 5% to 4%.Interpretation — Repeated metal ion measurements in unilateral ReCap-M2A-Magnum patients in a mean 2-year time interval did not show any increase. Long-term ion levels are, however, not yet known.
机译:背景与目的—全血(WB)钴(Co)和铬(Cr)离子水平在金属对金属全髋关节置换术(MoM THR)的随访中起着重要作用。我们首先调查了ReCap-M2A-Magnum THR患者重复测量后WB Co或Cr水平是否发生变化,其次,确定了有多少患者WB Co或Cr水平超过安全上限(患者和方法— 2005年至2012年间,我们机构对1,329例手术(1,188例患者)使用了Recap-M2A-Magnum THR。我们确定了所有单侧患者(n = 319) ReCap-M2A-Magnum植入物至少经过两次重复的金属离子测量,第一次采血平均在手术后5.5年(1.8-9.3),第二次采血平均在第一次手术后2年(0.5-3)。结果-在重复测量中,WB Co和Cr离子的中值水平分别从1.40(0.40–63)ppb降至1.10(0.20–68)ppb和从1.60(0.60–13.0)ppb降至1.10(0.30–19.0)ppb。初始测量时,有7%的Co离子值超过SUL,而对照测量中,有7%的Co离子值超过SUL。在测量间隔中,超过安全上限(SUL)的Cr离子值比例从5%降低到4%。解释—在单侧ReCap-M2A-Magnum患者中,平均2年时间间隔内重复进行金属离子测量显示任何增加。然而,长期的离子水平尚不清楚。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号