Morphological Comparison of Blood Vessels that were Heated with a Radiofrequency Device or a 1470-nm Laser and a Radial 2Ring Fiber

机译:用射频装置或1470-nm激光和径向2环光纤加热的血管的形态比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Introduction: Radio waves and lasers can be used as heat sources during endovenous thermal ablation (EVTA) for saphenous vein insufficiency. A morphological comparison of veins that had been treated with EVTA was performed between those treated with an endovenous closure system (a radiofrequency [RF] system) and those treated with a Radial 2Ring fiber connected to a 1470-nm laser generator (2R).>Methods: The experiment was conducted in a system that reproduces the physiological conditions found in the saphenous veins during EVTA. The 2R experiment was performed at two different power levels, 60 J/cm (2R-60) and 90 J/cm (2R-90). The heated vessels were morphologically examined in detail, and the detected morphological changes were classified into three groups: low-temperature changes (LTC), mid-temperature changes (MTC), and high-temperature changes (HTC). The thickness of the layers exhibiting each type of change was measured.>Results: In the 2R groups, HTC, MTC, and LTC were observed from the superficial to deep layers. In the 2R-60 group, the layers exhibiting LTC, MTC, and HTC were 17 ± 3.2, 42 ± 10.5, and 190 ± 14.6 µm thick, respectively. In the 2R-90 group, these layers were 14 ± 4.0, 105 ± 64.2, and 363 ± 71.3 µm thick, respectively. In the RF group, only LTC were observed (thickness: 251 ± 72.6 µm).>Conclusions: The RF device was able to heat the target vessels more efficiently than the laser device. (This article is a translation of Jpn J Phlebol 2015; 26: 23–8.)
机译:>简介:在大隐静脉功能不全的静脉热消融(EVTA)期间,无线电波和激光可用作热源。在经静脉闭合系统(射频[RF]系统)处理过的静脉和与1470 nm激光发生器(2R)连接的Radial 2Ring光纤处理过的静脉之间进行了EVTA处理过的静脉的形态比较。 strong>方法:该实验是在可重现EVTA期间在大隐静脉中发现的生理条件的系统中进行的。 2R实验是在两种不同的功率水平下进行的,分别为60 J / cm(2R-60)和90 J / cm(2R-90)。对加热的容器进行详细的形态学检查,并将检测到的形态变化分为三类:低温变化(LTC),中温变化(MTC)和高温变化(HTC)。测量表现出每种类型变化的层的厚度。>结果:在2R组中,从表层到深层都观察到了HTC,MTC和LTC。在2R-60组中,显示LTC,MTC和HTC的层分别为17±3.2、42±10.5和190±14.6 µm厚。在2R-90组中,这些层的厚度分别为14±4.0、105±64.2和363±71.3 µm。在RF组中,仅观察到LTC(厚度:251±72.6 µm)。>结论: RF设备比激光设备能够更有效地加热目标血管。 (本文是Jpn J Phlebol 2015的译文; 26:23-8。)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号