首页> 美国卫生研究院文献>Applied and Environmental Microbiology >Aerosolization of Respirable Droplets from a Domestic Spa Pool and the Use of MS-2 Coliphage and Pseudomonas aeruginosa as Markers for Legionella pneumophila
【2h】

Aerosolization of Respirable Droplets from a Domestic Spa Pool and the Use of MS-2 Coliphage and Pseudomonas aeruginosa as Markers for Legionella pneumophila

机译:家用温泉池中可吸入液滴的气雾化以及MS-2鹅毛和铜绿假单胞菌作为嗜肺军团菌标记的用途

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Legionnaires' disease can result when droplets or aerosols containing legionella bacteria are inhaled and deposited in the lungs. A number of outbreaks have been associated with the use of a spa pool where aeration, a high water temperature, and a large and variable organic load make disinfectant levels difficult to maintain. Spa pool ownership is increasing, and the aim of this study, using two surrogate organisms (MS-2 coliphage and Pseudomonas aeruginosa [a natural contaminant]), was to assess the potential risk to domestic users when disinfection fails. A representative “entry level” domestic spa pool was installed in an outdoor courtyard. The manufacturer's instructions for spa pool maintenance were not followed. A cyclone sampler was used to sample the aerosols released from the spa pool with and without activation of the air injection system. Samples were taken at increasing heights and distances from the pool. An aerodynamic particle sizer was used to measure the water droplet size distribution at each sample point. When the air injection system was inactivated, neither surrogate organism was recovered from the air. On activation of the air injection system, the mean mass of droplets within the respirable range (10 cm above the water line) was 36.8 μg cm−3. This corresponded to a mean air concentration of P. aeruginosa of 350 CFU m−3. From extrapolation from animal data, the estimated risk of infection from aerosols contaminated with similar concentrations of Legionella pneumophila was 0.76 (males) and 0.65 (females). At 1 m above and/or beyond the pool, the mean aerosol mass decreased to 0.04 μg cm−3 and corresponded to a 100-fold reduction in mean microbial air concentration. The estimated risk of infection at this distance was negligible.
机译:吸入含有军团菌细菌的飞沫或气溶胶并沉积在肺部,可能导致军团病。使用水疗池会引起许多爆发,其中的曝气,高水温和大量可变的有机物使消毒剂的含量难以维持。温泉浴池所有权的增加,并且本研究的目的是使用两种替代生物(MS-2噬菌体和铜绿假单胞菌[一种天然污染物])来评估消毒失败对家庭用户的潜在风险。一个有代表性的“入门级”家庭水疗池安装在室外庭院中。未遵循制造商对水疗池维护的说明。使用旋流器采样器来采样在启用和不启用空气注入系统的情况下从温泉池释放的气溶胶。从池中增加的高度和距离处采集样品。空气动力学粒度仪用于测量每个采样点的水滴尺寸分布。停用空气喷射系统后,没有从空气中回收任何替代生物。激活空气喷射系统后,可吸入范围(水线上方10 cm)内的平均液滴质量为36.8μgcm -3 。这对应于铜绿假单胞菌的平均空气浓度为350 CFU m -3 。从动物数据推断,估计被相似浓度的军团菌污染的气溶胶感染的风险为0.76(男性)和0.65(女性)。在池上方和/或上方1 m处,平均气溶胶质量降至0.04μgcm -3 ,对应于平均微生物空气浓度降低了100倍。在此距离下感染的估计风险可以忽略不计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号