首页> 美国卫生研究院文献>Applied and Environmental Microbiology >Microbiological Evaluation of a Range of Disinfectant Products To Control Mixed-Species Biofilm Contamination in a Laboratory Model of a Dental Unit Water System
【2h】

Microbiological Evaluation of a Range of Disinfectant Products To Control Mixed-Species Biofilm Contamination in a Laboratory Model of a Dental Unit Water System

机译:牙科产品水系统实验室模型中一系列控制混合产品生物膜污染的消毒产品的微生物学评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Dental unit water system (DUWS) tubing harbors complex multispecies biofilms that are responsible for high microbial levels at the distal outlet. The aim of this study was to use an established biofilm laboratory model to simulate biofouling of DUWS to evaluate practical, cost-effective, and evidence-based methods of microbial decontamination. Reproducible biofilms were developed in the model over 14 days; decontamination was assessed using total viable counts (TVC) and microscopic-image analysis techniques to view the inner surface of tubing. Flushing did not reduce the biofilm coverage or TVC. Combizyme and ozone did not completely eliminate the viable bacteria (70 and 65% reduction in biofilm TVC, respectively), nor did they remove the biofilm (45 and 57% reduction in biofilm coverage, respectively). Chlorhexidine and Bio2000 (active agent: ethanol and chlorhexidine), Tegodor and Gigasept Rapid (aldehyde based), and Grotanol (hydroxide based) completely eliminated the TVC but did not completely remove biofilm (31, 53 33, 34, and 64.9% reduction of biofilm coverage, respectively). Other products including Grotanol Flussig (phenol based), Betadine (povidone-iodine based), Alpron (chlorite based), and the hydroxide-containing products Sporklenz, Sterilex Ultra, Dialox, Sterilox, Sanosil, Oxigenal, and Grotanat Bohrerbad resulted in a 100% reduction in the biofilm TVC and a >95% reduction in biofilm coverage. The study demonstrated that while many disinfectants achieve a sufficient reduction in TVC they may not necessarily remove unwanted biofilm from the tubing surfaces as tested in this laboratory-controlled biofilm model.
机译:牙科用水系统(DUWS)的管道中包含复杂的多种生物膜,这些生物膜负责远端出口处的高微生物水平。这项研究的目的是使用已建立的生物膜实验室模型来模拟DUWS的生物污染,以评估实用,具有成本效益和基于证据的微生物净化方法。该模型在14天内开发了可复制的生物膜;使用总可行计数(TVC)和显微图像分析技术评估消毒效果,以查看管道的内表面。冲洗并没有减少生物膜覆盖率或TVC。 Combizyme和臭氧不能完全消除活菌(生物膜TVC分别降低70%和65%),也不能消除生物膜(生物膜覆盖率分别降低45%和57%)。洗必泰和Bio2000(活性剂:乙醇和洗必泰),Tegodor和Gigasept Rapid(基于醛)和谷氨醇(基于氢氧化物)完全消除了TVC,但没有完全去除生物膜(降低了31%,53%,33%,34%和64.9%)生物膜覆盖率)。其他产品包括Grotanol Flussig(基于酚),Betadine(基于聚维酮-碘),Alpron(基于亚氯酸盐)以及含氢氧化物的产品Sporklenz,Sterilex Ultra,Dialox,Sterilox,Sanosil,Oxigenal和Grotanat Bohrerbad产生了100生物膜TVC减少了%,生物膜覆盖率减少了> 95%。这项研究表明,尽管许多消毒剂可实现TVC的充分降低,但它们不一定像本实验室控制的生物膜模型所测试的那样从管道表面去除多余的生物膜。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号