Dental-unit water systems (DUWS) harbor bacterial biofilms, which may serve as a haven for pathogens. The aim of this study was to investigate the microbial load of water from DUWS in general dental practices and the biofouling of DUWS tubing. Water and tube samples were taken from 55 dental surgeries in southwestern England. Contamination was determined by viable counts on environmentally selective, clinically selective, and pathogen-selective media, and biofouling was determined by using microscopic and image analysis techniques. Microbial loading ranged from 500 to 105 CFU · ml−1; in 95% of DUWS water samples, it exceeded European Union drinking water guidelines and in 83% it exceeded American Dental Association DUWS standards. Among visible bacteria, 68% were viable by BacLight staining, but only 5% of this “viable by BacLight” fraction produced colonies on agar plates. Legionella pneumophila, Mycobacterium spp., Candida spp., and Pseudomonas spp. were detected in one, five, two, and nine different surgeries, respectively. Presumptive oral streptococci and Fusobacterium spp. were detected in four and one surgeries, respectively, suggesting back siphonage and failure of antiretraction devices. Hepatitis B virus was never detected. Decontamination strategies (5 of 55 surgeries) significantly reduced biofilm coverage but significantly increased microbial numbers in the water phase (in both cases, P < 0.05). Microbial loads were not significantly different in DUWS fed with soft, hard, deionized, or distilled water or in different DUWS (main, tank, or bottle fed). Microbiologically, no DUWS can be considered “cleaner” than others. DUWS deliver water to patients with microbial levels exceeding those considered safe for drinking water.
机译:牙科用水系统(DUWS)带有细菌生物膜,可作为病原体的避风港。这项研究的目的是研究一般牙科实践中来自DUWS的水的微生物负荷以及DUWS管道的生物污染。水和试管样本取自英格兰西南部的55个牙科诊所。通过在环境选择性,临床选择性和病原体选择性培养基上的可行计数来确定污染,并通过使用显微镜和图像分析技术确定生物污染。微生物负荷范围为500至10 5 CFU·ml -1 ;在95%的DUWS水样本中,它超过了欧盟饮用水准则,在83%的样本中,它超过了美国牙科协会DUWS的标准。在可见细菌中,有68%通过BacLight染色是可行的,但是这种“通过BacLight”存活的分数只有5%在琼脂平板上产生菌落。肺炎军团菌,分枝杆菌属,念珠菌属和假单胞菌属。分别在1、5、2和9个不同的手术中被检测到。推定口服链球菌和镰刀菌属。分别在四和一手术中被发现,提示虹吸回吸和抗收缩装置失败。从未检测到乙型肝炎病毒。去污策略(55个手术中的5个)显着减少了生物膜的覆盖范围,但显着增加了水相中的微生物数量(在两种情况下,P <0.05)。用软水,硬水,去离子水或蒸馏水喂养的DUWS或使用不同DUWS(主,水箱或瓶装)的DUWS的微生物负荷没有显着差异。在微生物学上,没有任何DUWS被认为比其他更“清洁”。 DUWS为微生物水平超过饮用水安全的患者提供水。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号