首页> 美国卫生研究院文献>Applied and Environmental Microbiology >National field evaluation of a defined substrate method for the simultaneous enumeration of total coliforms and Escherichia coli from drinking water: comparison with the standard multiple tube fermentation method.
【2h】

National field evaluation of a defined substrate method for the simultaneous enumeration of total coliforms and Escherichia coli from drinking water: comparison with the standard multiple tube fermentation method.

机译:国家现场评估确定的底物方法用于同时从饮用水中计数总大肠菌群和大肠杆菌:与标准多管发酵法比较。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A defined substrate method was developed to simultaneously enumerate total coliforms and Escherichia coli from drinking waters without the need for confirmatory or completed tests. It is a new method based on technology that uses a hydrolyzable substrate as a specific indicator-nutrient for the target microbes. No equipment other than a 35 degrees C incubator and long-wavelength (366-nm) light is necessary. To perform the test, one only has to add water to the powdered ingredients in a tube or flask. If total coliforms are present in the water sample, the solution will change from its normal colorless state (no target microbes present) to yellow. The specific presence of E. coli will cause the same tube to fluoresce under a longwave (366-nm) UV lamp. The test, called Autoanalysis Colilert (AC), was compared with Standard Methods for the Examination of Water and Wastewater 10-tube multiple tube fermentation (MTF) in a national evaluation. Five utilities, representing six U.S. Environmental Protection Agency regions, participated. All water samples came from distribution systems. Split samples from a wide variety of water sources were analyzed for the MPN-versus-MPN comparison. A total of 1,086 tubes were positive by MTF, and 1,279 were positive by AC. There was no statistical difference between MTF and AC. Species identifications from positive tubes confirmed the sensitivity of the AC. A national evaluation of the AC test showed that it: (i) was as sensitive as Standard Methods MTF, (ii) specifically enumerated 1 total coliform per 100 ml, in a maximum of 24 h, (iii) simultaneously enumerated 1 E. coli per 100 ml in the same analysis, (iv) was not subject to false-positive or false-negative results by heterotrophic bacteria, (v) did not require confirmatory tests, (vi) grew injured coliforms, (vii) was easy to inoculate, and (viii) was very easy to interpret.
机译:开发了确定的底物方法,可同时从饮用水中枚举大肠菌群和大肠杆菌,而无需进行确认性或完整的测试。这是一种基于技术的新方法,该方法使用可水解底物作为目标微生物的特定指示剂营养素。除了35摄氏度的培养箱和长波长(366 nm)的光以外,不需要任何其他设备。要进行测试,只需要将水加到试管或烧瓶中的粉状成分中即可。如果水样中存在大肠菌群,溶液将从正常的无色状态(不存在目标微生物)变为黄色。大肠杆菌的特定存在会导致同一根管在长波(366 nm)紫外线灯下发出荧光。在一项国家评估中,该名为Autoanalysis Colilert(AC)的测试与10管多管发酵水和废水的标准检测方法(MTF)进行了比较。代表美国环境保护署六个地区的五家公用事业公司参加了会议。所有水样均来自分配系统。分析了来自多种水源的分离样品,以进行MPN与MPN的比较。 MTF共有1,086个试管阳性,AC共有1,279例阳性。 MTF和AC之间没有统计学差异。从阳性管中鉴定出的物种证实了AC的灵敏度。一项AC测试的国家评估表明:(i)与标准方法MTF一样灵敏,(ii)每100毫升最多枚举1个大肠菌群最多24小时,(iii)同时枚举1个大肠杆菌每100毫升在同一分析中,(iv)不受异养细菌的假阳性或假阴性结果影响,(v)不需要进行验证性测试,(vi)受伤的大肠菌生长,(vii)易于接种,而且(viii)解释起来很容易。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号