Reliability of Using Retinal Vascular Fractal Dimension as a Biomarker in the Diabetic Retinopathy Detection

机译:在糖尿病性视网膜病变检测中使用视网膜血管分形维数作为生物标志物的可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The retinal fractal dimension (FD) is a measure of vasculature branching pattern complexity. FD has been considered as a potential biomarker for the detection of several diseases like diabetes and hypertension. However, conflicting findings were found in the reported literature regarding the association between this biomarker and diseases. In this paper, we examine the stability of the FD measurement with respect to (1) different vessel annotations obtained from human observers, (2) automatic segmentation methods, (3) various regions of interest, (4) accuracy of vessel segmentation methods, and (5) different imaging modalities. Our results demonstrate that the relative errors for the measurement of FD are significant and FD varies considerably according to the image quality, modality, and the technique used for measuring it. Automated and semiautomated methods for the measurement of FD are not stable enough, which makes FD a deceptive biomarker in quantitative clinical applications.
机译:视网膜分形维数(FD)是脉管分支模式复杂性的量度。 FD被认为是检测多种疾病(如糖尿病和高血压)的潜在生物标记。然而,在报道的文献中发现了与该生物标记物和疾病之间的关联相矛盾的发现。在本文中,我们针对(1)从人类观察者获得的不同血管注释,(2)自动分割方法,(3)感兴趣的各个区域,(4)血管分割方法的准确性, (5)不同的成像方式。我们的结果表明,FD测量的相对误差很大,并且FD会根据图像质量,模态和用于测量它的技术而有很大不同。自动和半自动测量FD的方法不够稳定,这使得FD在定量临床应用中成为欺骗性生物标志物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号