Comparison of Intraocular Pressure before and after Laser In Situ Keratomileusis Refractive Surgery Measured with Perkins Tonometry Noncontact Tonometry and Transpalpebral Tonometry

机译:用珀金斯眼压计非接触式眼压计和经睑眼压计测量激光原位角膜磨镶屈光手术前后眼压的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purpose. To compare the intraocular pressure (IOP) before and after Laser In Situ Keratomileusis (LASIK), measured by Diaton, Perkins, and noncontact air pulse tonometers. Methods. Fifty-seven patients with a mean age of 34.88 were scheduled for myopia LASIK treatment. Spherical equivalent refraction (SER), corneal curvature (K), and central corneal thickness (CCT) and superior corneal thickness (SCT) were obtained before and after LASIK surgery. IOP values before and after surgery were measured using Diaton, Perkins, and noncontact air pulse tonometers. Results. The IOP values before and after LASIK surgery using Perkins tonometer and air tonometers were statistically significant (p < 0.05). However, no significant differences were found (p > 0.05) for IOP values measured with Diaton tonometer. CCT decreases significantly after surgery (p < 0.05) but no statistical differences were found in SCT (p = 0.08). Correlations between pre- and postsurgery were found for all tonometers used, with p = 0.001 and r = 0.434 for the air pulse tonometer, p = 0.008 and r = 0.355 for Perkins, and p < 0.001 and r = 0.637 for Diaton. Conclusion. Transpalpebral tonometry may be useful for measuring postsurgery IOP after myopic LASIK ablation because this technique is not influenced by the treatment.
机译:目的。比较Diaton,Perkins和非接触式空气脉冲眼压计测量的激光原位角膜磨镶术(LASIK)前后的眼压(IOP)。方法。平均年龄34.88岁的57例患者计划接受近视LASIK治疗。在LASIK手术前后,分别获得等效球面屈光度(SER),角膜曲率(K),中央角膜厚度(CCT)和上角膜厚度(SCT)。使用Diaton,Perkins和非接触式空气脉冲眼压计测量手术前后的IOP值。结果。在使用Perkins眼压计和空气眼压计的LASIK手术前后,IOP值具有统计学意义(p <0.05)。但是,使用Diaton眼压计测量的IOP值没有发现显着差异(p> 0.05)。手术后CCT显着降低(p <0.05),但SCT中无统计学差异(p = 0.08)。对于所有使用的眼压计,都发现手术前后的相关性,其中空气脉冲眼压计的p = 0.001和r = 0.434,Perkins的p = 0.008和r = 0.355,而Diaton的p <0.001和r = 0.637。结论。经眼睑眼压测量法可用于测量近视LASIK消融术后的术后IOP,因为该技术不受治疗的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号