Comparison of intraocular pressures after myopic laser-assisted subepithelial keratectomy: Tonometry-pachymetry, Goldmann applanation tonometry, dynamic contour tonometry, and noncontact tonometry

机译:近视激光辅助上皮下角膜切除术后眼压的比较:眼压-测厚法,Goldmann压平眼压计,动态轮廓眼压计和非接触眼压计

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: To compare intraocular pressure (IOP) measurements using a new tonometer-pachymeter device (Tonopachy), Goldmann applanation tonometry (GAT), dynamic contour tonometry (DCT), and noncontact tonometry (NCT) before and after myopic laser-assisted subepithelial keratectomy (LASEK). Setting: Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea. Design: Prospective comparative observational study. Methods: Nine IOP values were measured using 4 tonometers (6 IOPs by tonometer-pachymeter and 1 each by GAT, DCT, and NCT) and compared preoperatively and 3 months postoperatively. Of the 6 IOP values measured by the tonometer-pachymeter, 1 showed uncorrected IOP and 5 indicated central corneal thickness (CCT)-corrected IOPs through different formulas. Results: Preoperatively and postoperatively, the means of 9 IOP values measured by 4 tonometers were statistically different. The IOP measurements by the tonometer-pachymeter correlated with all other IOP values preoperatively; however, there was no correlation with IOP measurements using DCT postoperatively. Some IOPs using the tonometer-pachymeter were interchangeable with those using GAT preoperatively, but not with DCT preoperatively or postoperatively. The corrected IOP values of the tonometer-pachymeter formula 3 and DCT did not change after surgery. The percentage change in CCT and corneal curvature and change in diopters correlated with the percentage change in IOP measurements by GAT and NCT but not with those using DCT and the tonometer-pachymeter. Conclusion: Among the 9 IOP values, corrected IOP using the tonometer-pachymeter formula 3 showed similar IOP values after LASEK, as did DCT. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
机译:目的:比较近视激光辅助上皮下角膜缘切除术前后使用新型眼压计-测厚仪设备(Tonopachy),Goldmann压平眼压计(GAT),动态轮廓眼压计(DCT)和非接触眼压计(NCT)的眼内压(IOP)测量结果(LASEK)。地点:延世大学医学院眼科视觉研究所,韩国首尔。设计:前瞻性比较观察研究。方法:使用4眼压计测量9个IOP值(眼压计-眼压计测量6个IOP,GAT,DCT和NCT分别测量1个),并在术前和术后3个月进行比较。通过眼压计-测厚仪测得的6个IOP值中,有1个显示未矫正的IOP,而5个显示了通过不同公式计算的中央角膜厚度(CCT)矫正的IOP。结果:术前和术后,使用4眼压计测量的9个IOP值的平均值具有统计学差异。眼压计-测厚仪的眼压测量值与术前所有其他眼压值相关。但是,术后DCT与IOP测量没有相关性。使用眼压计-测厚仪的一些眼压可以与术前使用GAT的眼压互换,但不能在术前或术后与DCT互换。眼压计-测厚仪公式3和DCT的校正后的IOP值在手术后没有变化。 CCT和角膜曲率的变化百分比以及屈光度的变化与GAT和NCT的IOP测量的百分比变化相关,而与DCT和眼压计-测厚仪的变化无关。结论:在9个IOP值中,使用眼压计-测厚仪公式3校正的IOP与LASEK相比在LASEK后显示出相似的IOP值。财务披露:没有任何作者对所提及的任何材料或方法有财务或专有利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号