Purpose. To assess the reliability and comparability of measuring central corneal thickness (CCT) and thinnest corneal thickness (TCT) using a new Scheimpflug-Placido analyzer (TMS-5, Japan) and ultrasound (US) pachymetry. Methods. Seventy-six healthy subjects were prospectively measured 3 times by 1 operator using the TMS-5, 3 additional consecutive scans were performed by a second operator, and ultrasound (US) pachymetry measurements were taken. The test-retest repeatability (TRT), coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were calculated to evaluate intraoperator repeatability and interoperator reproducibility. Agreement among the devices was assessed using Bland-Altman plots and 95% limits of agreement (LoA). Results. The intraoperators TRT and CoV were <19 μm and 2.0%, respectively. The interoperators TRT and CoV were <12 μm and 1.0%, respectively, and ICC was >0.90. The mean CCT and TCT measurements using the TMS-5 were 15.97 μm (95% LoA from −26.42 to −5.52 μm) and 20.32 μm (95% LoA from −30.67 to −9.97 μm) smaller, respectively, than those using US pachymetry. Conclusions. The TMS-5 shows good repeatability and reproducibility for measuring CCT and TCT in normal subjects but only moderate agreement with US pachymetry results. Caution is warranted before using these techniques interchangeably.
机译:目的。为了评估使用新型Scheimpflug-Placido分析仪(日本TMS-5)和超声(美国)测厚仪测量中央角膜厚度(CCT)和最薄角膜厚度(TCT)的可靠性和可比性。方法。 1名操作员使用TMS-5对76名健康受试者进行了3次前瞻性测量,第二名操作员进行了3次其他连续扫描,并进行了超声(US)测厚法测量。计算重测重复性(TRT),变异系数(CoV)和组内相关系数(ICC),以评估操作员内的重复性和操作员间的可重复性。使用Bland-Altman图和95%的协议限制(LoA)评估设备之间的协议。结果。术中TRT和CoV分别小于19μm和2.0%。互操作者的TRT和CoV分别小于12μm和1.0%,ICC大于0.90。使用TMS-5的平均CCT和TCT测量值分别比使用美国测厚仪的测量值小15.97μm(从-26.42到-5.52μm的95%LoA)和20.32μm(从-30.67到-9.97μm的95%LoA)。 。结论。 TMS-5在正常受试者中测量CCT和TCT时显示出良好的可重复性和可重复性,但与US测厚法的结果仅相符。在交替使用这些技术之前,请务必谨慎。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号