首页> 美国卫生研究院文献>Journal of Pharmaceutical Analysis >Sensing of chlorpheniramine in pharmaceutical applications by sequential injector coupled with potentiometer
【2h】

Sensing of chlorpheniramine in pharmaceutical applications by sequential injector coupled with potentiometer

机译:顺序注射器与电位计联用在制药应用中检测扑尔敏

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This paper reports on development of a system consisting of a portable sequential injector coupled with potentiometric unit for sensing of chlorpheniramine (CPA), based on the reaction of CPA with potassium permanganate in acidic media. Various experimental conditions affecting the potential intensity were studied and incorporated into the procedure. Under the optimum conditions, linear relationship between the CPA concentration and peak area was obtained for the concentration range of 0.1–50 ppm. The method reflects good recovery with relative standard deviation (RSD)<3%. The detection limit was 0.05 ppm. The developed method was successfully applied for determination of CPA in pure form and in pharmaceutical dosage forms. The results, obtained using the method, are in accord with the results of the British pharmacopoeia method. In addition to its accuracy and precision, the method has the advantages of being simple, inexpensive and rapid.
机译:本文基于CPA与高锰酸钾在酸性介质中的反应,报告了一种系统的开发,该系统由便携式顺序注射器和电位计单元组成,用于检测扑尔敏(CPA)。研究了影响电势强度的各种实验条件,并将其纳入程序中。在最佳条件下,对于0.1-50 ppm的浓度范围,CPA浓度与峰面积之间存在线性关系。该方法反映出良好的回收率,相对标准偏差(RSD)<3%。检出限为0.05 ppm。所开发的方法已成功地用于测定纯净形式和药物剂型中的CPA。使用该方法获得的结果与英国药典方法的结果一致。除了其准确性和精确性之外,该方法还具有简单,廉价和快速的优点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号