首页> 美国卫生研究院文献>British Journal of Cancer >Reliability of cyclin A assessment on tissue microarrays in breast cancer compared to conventional histological slides
【2h】

Reliability of cyclin A assessment on tissue microarrays in breast cancer compared to conventional histological slides

机译:与传统组织学切片相比Cyclin A对乳腺癌组织微阵列的评估可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Cyclin A has in some studies been associated with poor breast cancer survival, although all studies have not confirmed this. Its prognostic significance in breast cancer needs evaluation in larger studies. Tissue microarray (TMA) technique allows a simultaneous analysis of large amount of tumours on a single microscopic slide. This makes a rapid screening of molecular markers in large amount of tumours possible. Because only a small tissue sample of each tumour is punched on an array, the question has arisen about the representativeness of TMA when studying markers that are expressed in only a small proportion of cells. For this reason, we wanted to compare cyclin A expression on TMA and on traditional large sections. Two breast cancer TMAs were constructed of 200 breast tumours diagnosed between 1997–1998. TMA slides and traditional large section slides of these 200 tumours were stained with cyclin A antibody and analysed by two independent readers. The reproducibility of the two readers' results was good or even very good, with kappa values 0.71–0.87. The agreement of TMA and large section results was good with kappa value 0.62–0.75. Cyclin A overexpression was significantly (P<0.001) associated with oestrogen receptor and progesterone receptor negativity and high grade both on TMA and large sections. Cyclin A overexpression was significantly associated with poor metastasis-free survival both on TMA and large sections. The relative risks for metastasis were similar on TMA and large sections. This study suggests that TMA technique could be useful to study histological correlations and prognostic significance of cyclin A on breast cancer on a large scale.
机译:在某些研究中,细胞周期蛋白A与较差的乳腺癌生存率有关,尽管所有研究均未证实这一点。其在乳腺癌中的预后意义需要在更大的研究中进行评估。组织微阵列(TMA)技术允许在单个显微镜载玻片上同时分析大量肿瘤。这使得可以快速筛选大量肿瘤中的分子标记。因为每个肿瘤的小组织样本仅被打在阵列上,所以当研究仅在小部分细胞中表达的标志物时,就出现了TMA的代表性问题。因此,我们想比较TMA和传统大切片上cyclin A的表达。在1997年至1998年之间,诊断出200例乳腺肿瘤构成了两个乳腺癌TMA。用cyclin A抗体对这200个肿瘤的TMA载玻片和传统的大切片载玻片进行染色,并由两个独立的阅读器进行分析。两位读者的结果的可重复性很好,甚至非常好,kappa值为0.71-0.87。 TMA与大切片结果吻合良好,kappa值为0.62-0.75。在TMA和大切片上,细胞周期蛋白A的过表达与雌激素受体和孕激素受体的阴性和高分显着相关(P <0.001)。细胞周期蛋白A的过表达与TMA和大切片的无转移生存期差显着相关。 TMA和大切片上转移的相对风险相似。这项研究表明,TMA技术可用于大规模研究细胞周期蛋白A在乳腺癌中的组织学相关性和预后意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号