Inactivation and recovery kinetics of L-type calcium currents were '/> Kinetics of inactivation and restoration from inactivation of the L-type calcium current in human myotubes
首页> 美国卫生研究院文献>The Journal of Physiology >Kinetics of inactivation and restoration from inactivation of the L-type calcium current in human myotubes
【2h】

Kinetics of inactivation and restoration from inactivation of the L-type calcium current in human myotubes

机译:人肌管中L型钙电流失活和恢复的动力学

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

class="enumerated" style="list-style-type:decimal">Inactivation and recovery kinetics of L-type calcium currents were measured in myotubes derived from satellite cells of human skeletal muscle using the whole cell patch clamp technique.The time course of inactivation at potentials above the activation threshold was obtained from the decay of the current during 15 s depolarizing pulses. At subthreshold potentials, prepulses of different durations, followed by +20 mV test pulses, were used. The time course could be well described by single exponential functions of time. The time constant decreased from 17.8 ± 7.5 s at -30 mV to 1.78 ± 0.15 s at +50 mV.Restoration from inactivation caused by 15 s depolarization to +20 mV was slowed by depolarization in the restoration interval. The time constant increased from 1.11 ± 0.17 s at -90 mV to 7.57 ± 2.54 s at -10 mV.Restoration showed different kinetics depending on the duration of the conditioning depolarization. While the time constant was similar at restoration potentials of -90 and -50 mV after a 1 s conditioning prepulse, it increased with increasing prepulse duration at -50 mV and decreased at -90 mV.The experiments showed that the rates of inactivation and restoration of the L-type calcium current in human myotubes were not identical when observed at the same potential. The results indicate the presence of more than one inactivated state and point to different voltage-dependent pathways for inactivation and restoration.
机译:class =“ enumerated” style =“ list-style-type:decimal”> <!-list-behavior =枚举前缀-word = mark-type = decimal max-label-size = 0-> 使用全细胞膜片钳技术测量了来自人体骨骼肌卫星细胞的肌管中L型钙电流的失活和恢复动力学。 获得了在高于激活阈值的电势下失活的时间过程由15秒去极化脉冲期间电流的衰减引起。在亚阈值电势下,使用了不同持续时间的预脉冲,然后是+20 mV测试脉冲。时间过程可以通过时间的单指数函数很好地描述。时间常数从-30 mV时的17.8±7.5 s降至+50 mV时的1.78±0.15 s。 在恢复间隔中通过去极化使从15 s去极化导致的失活恢复到+20 mV 。时间常数从-90 mV时的1.11±0.17 s增加到-10 mV时的7.57±2.54 s。 恢复取决于调解去极化的持续时间而显示出不同的动力学。在1 s的条件预脉冲后,恢复电位分别为-90和-50 mV时,时间常数相似,但随着-50 mV时预脉冲持续时间的增加而增加,而在-90 mV时则降低。当在相同电位下观察时,人肌管中L型钙电流的失活和恢复速率不同。结果表明存在一种以上的失活状态,并指出了不同的电压依赖性失活和恢复途径。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号