首页> 美国卫生研究院文献>The British Journal of Ophthalmology >Twelve hour reproducibility of choroidal blood flow parameters in healthy subjects
【2h】

Twelve hour reproducibility of choroidal blood flow parameters in healthy subjects

机译:健康受试者脉络膜血流参数的十二小时再现性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Aims/background: To investigate the reproducibility and potential diurnal variation of choroidal blood flow parameters in healthy subjects over a period of 12 hours.>Methods: The choroidal blood flow parameters of 16 healthy non-smoking subjects were measured at five time points during the day (8:00, 11:00, 14:00, 17:00, and 20:00). Outcome parameters were pulsatile ocular blood flow as assessed by pneumotonometry, fundus pulsation amplitude as assessed by laser interferometry, blood velocities in the opthalmic and posterior ciliary arteries as assessed by colour Doppler imaging, and choroidal blood flow, volume, and velocity as assessed by fundus camera based laser Doppler flowmetry. The coefficient of variation and the maximum change from baseline in an individual were calculated for each outcome parameter.>Results: None of the techniques used found a diurnal variation in choroidal blood flow. Coefficients of variation were within 2.9% and 13.6% for all outcome parameters. The maximum change from baseline in an individual was much higher, ranging from 11.2% to 58.8%.>Conclusions: These data indicate that in healthy subjects the selected techniques provide adequate reproducibility to be used in clinical studies. Variability may, however, be considerably higher in older subjects or subjects with ocular disease. The higher individual differences in flow parameter readings limit the use of the techniques in clinical practice. To overcome problems with measurement validity, a clinical trial should include as many choroidal blood flow outcome parameters as possible to check for consistency.
机译:>目的/背景:研究健康受试者在12小时内脉络膜血流参数的可重复性和潜在的昼夜变化。>方法: 16种脉络膜血流参数在一天中的五个时间点(8:00、11:00、14:00、17:00和20:00)对健康的非吸烟受试者进行了测量。结果参数是通过眼压计评估的脉动眼血流量,通过激光干涉术评估的眼底搏动幅度,通过彩色多普勒成像评估的眼睫状和后睫状动脉的血流速度以及通过眼底评估的脉络膜血流量,体积和速度基于摄像头的激光多普勒血流仪。计算每个结果参数的个体变异系数和相对于基线的最大变化。>结果:所用技术均未发现脉络膜血流的昼夜变化。所有结果参数的变异系数在2.9%和13.6%之内。个体从基线的最大变化要高得多,范围从11.2%到58.8%。>结论:这些数据表明,在健康受试者中,所选技术可提供足够的可重复性以用于临床研究。但是,年龄较大的受试者或患有眼疾的受试者的变异性可能更高。流量参数读数中较高的个体差异限制了该技术在临床实践中的使用。为了克服测量有效性的问题,临床试验应包括尽可能多的脉络膜血流结果参数以检查一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号