首页> 外文期刊>British journal of ophthalmology >Twelve hour reproducibility of choroidal blood flow parameters in healthy subjects.
【24h】

Twelve hour reproducibility of choroidal blood flow parameters in healthy subjects.

机译:在健康受试者中脉络膜血流参数的十二小时再现性。

获取原文
获取原文并翻译 | 示例
           

摘要

Aims/background: To investigate the reproducibility and potential diurnal variation of choroidal blood flow parameters in healthy subjects over a period of 12 hours. METHODS: The choroidal blood flow parameters of 16 healthy non-smoking subjects were measured at five time points during the day (8:00, 11:00, 14:00, 17:00, and 20:00). Outcome parameters were pulsatile ocular blood flow as assessed by pneumotonometry, fundus pulsation amplitude as assessed by laser interferometry, blood velocities in the opthalmic and posterior ciliary arteries as assessed by colour Doppler imaging, and choroidal blood flow, volume, and velocity as assessed by fundus camera based laser Doppler flowmetry. The coefficient of variation and the maximum change from baseline in an individual were calculated for each outcome parameter. RESULTS: None of the techniques used found a diurnal variation in choroidal blood flow. Coefficients of variation were within 2.9% and 13.6% for all outcome parameters. The maximum change from baseline in an individual was much higher, ranging from 11.2% to 58.8%. CONCLUSIONS: These data indicate that in healthy subjects the selected techniques provide adequate reproducibility to be used in clinical studies. Variability may, however, be considerably higher in older subjects or subjects with ocular disease. The higher individual differences in flow parameter readings limit the use of the techniques in clinical practice. To overcome problems with measurement validity, a clinical trial should include as many choroidal blood flow outcome parameters as possible to check for consistency.
机译:目的/背景:研究健康受试者在12小时内的脉络膜血流参数的再现性和潜在的昼夜变化。方法:在一天中的五个时间点(8:00、11:00、14:00、17:00和20:00)测量16名健康非吸烟受试者的脉络膜血流参数。结果参数是通过眼压计评估的脉动眼血流量,通过激光干涉术评估的眼底搏动幅度,通过彩色多普勒成像评估的眼睫状和后睫状动脉的血流速度以及通过眼底评估的脉络膜血流量,体积和速度基于摄像头的激光多普勒血流仪。对于每个结果参数,计算个体的变异系数和相对于基线的最大变化。结果:所使用的技术均未发现脉络膜血流的昼夜变化。所有结果参数的变异系数在2.9%和13.6%之内。个人相对于基线的最大变化要高得多,范围从11.2%到58.8%。结论:这些数据表明,在健康受试者中,所选择的技术提供了足够的可重复性,可用于临床研究。但是,在老年受试者或患有眼疾的受试者中,变异性可能更高。流量参数读数的较高个体差异限制了该技术在临床实践中的使用。为了克服测量有效性的问题,临床试验应包括尽可能多的脉络膜血流结果参数以检查一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号