【2h】

Visual acuity in unilateral cataract.

机译:单侧白内障的视力。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

BACKGROUND: Patching the fellow eye in infancy is a well recognised therapy to encourage visual development in the lensectomised eye in cases of unilateral congenital cataract. The possibility of iatrogenic deficits of the fellow eye was investigated by comparing the vision of these patients with untreated unilateral patients and binocularly normal controls. METHODS: Sweep visual evoked potentials (VEPs) offer a rapid and objective method for estimating grating acuity. Sweep VEPs were used to estimate acuity in 12 children aged between 4 and 16 years who had had a congenital cataract removed in the first 13 weeks of life. The acuities of aphakic and fellow phakic eye were compared with the monocular acuities of similarly aged children who have good binocular vision, and with children with severe untreated uniocular visual impairment. Recognition linear acuities were measured with a linear Bailey-Lovie logMAR chart and compared with the sweep VEP estimates. RESULTS: A significant difference was found between Bailey-Lovie acuity of the fellow eye of the patient group and the right eye of binocular controls, and the good eye of uniocular impaired patients (one way ANOVA, p < 0.01). However, this was not evident for a similar comparison with sweep VEP estimates. There was no significant difference between the right and left eye acuities in binocular controls measured by the two techniques (paired t test). CONCLUSION: A loss of recognition acuity in the fellow phakic eye of patients treated for unilateral congenital cataract has been demonstrated with a logMAR chart. This loss was not apparent in children who have severe untreated uniocular visual impairment and may therefore be an iatrogenic effect of occlusion. An acuity loss was not apparent in the patient group using the sweep VEP method. Sweep VEP techniques have a place for objectively studying acuity in infants and in those whose communication difficulties preclude other forms of behavioural test. The mean sweep VEP acuity for the control groups is 20 cpd--that is, about 6/9. When acuities higher than this are under investigation--for example, in older children, slower transient VEP recording may be more appropriate, because higher spatial frequency patterns are not as visible at higher temporal rates (for example, 8 Hz used in sweep VEP recordings).
机译:背景:在婴儿期修补另一只眼是一种广为人知的疗法,可在单侧先天性白内障病例中鼓励切除晶状体的眼睛的视觉发育。通过将这些患者的视力与未经治疗的单侧患者和双眼正常对照进行比较,研究了另一只眼的医源性缺陷的可能性。方法:扫视视觉诱发电位(VEP)提供了一种快速而客观的方法来估算光栅的敏锐度。扫描VEP用于评估12例年龄在4到16岁之间的儿童的敏锐度,这些儿童在出生后的前13周内已去除了先天性白内障。将无晶状体和同晶状体眼的视力与双眼视力良好的相似年龄儿童以及未经治疗的严重单眼视力障碍的单眼视力进行了比较。使用线性Bailey-Lovie logMAR图表测量识别的线性敏锐度,并将其与扫描VEP估计值进行比较。结果:患者组的另一只眼和双眼对照的右眼的贝利-洛维视力与单眼受损患者的好眼之间存在显着差异(单因素方差分析,p <0.01)。但是,对于与扫描VEP估计的类似比较,这并不明显。通过两种技术(配对t检验)测量的双眼对照的右眼和左眼视力之间没有显着差异。结论:单侧先天性白内障患者的有晶状体眼同视力丧失已经通过logMAR图表证明。这种损失在患有严重未经治疗的单眼视力障碍的儿童中并不明显,因此可能是闭塞的医源性作用。使用扫描VEP方法在患者组中视力下降不明显。扫频VEP技术可以客观地研究婴儿以及那些因沟通困难而无法进行其他形式的行为测验的婴儿的敏锐度。对照组的平均扫描VEP视力为20 cpd,即约6/9。当正在研究高于此的视力时-例如,对于较大的孩子,较慢的瞬态VEP记录可能更合适,因为较高的空间频率模式在较高的时间速率下不可见(例如,扫描VEP记录中使用的8 Hz )。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号