Correlation of lens density measured using the Pentacam Scheimpflug system with the Lens Opacities Classification System III grading score and visual acuity in age-related nuclear cataract.

机译:使用Pentacam Scheimpflug系统测量的晶状体密度与年龄相关性核性白内障的“晶状体不透明度分类系统III”等级评分和视敏度的相关性。

获取原文
获取原文并翻译 | 示例
           

摘要

AIMS: To investigate the relationship between lens density measured with the Pentacam Scheimpflug System and grading score using the Lens Opacities Classification System (LOCS) III as well as that between lens density and visual acuity in age-related nuclear cataract patients. METHODS: Lens density and grading score were evaluated in 138 cases (180 eyes) with age-related nuclear cataract. LogMAR visual acuity was tested with the Early Treatment Diabetic Retinopathy Study chart. The correlations between lens density value and LOCS III nuclear opacity (NO) and nuclear colour (NC) grading score and that between lens density value and logMAR visual acuity were analysed. RESULTS: There was a linear increasing relationship between lens density value and LOCS III grading score in nuclear cataract patients. Lens density value had a stronger significant correlation with LOCS III NO score than that with NC score. The correlation between the nuclear lens density value and logMAR visual acuity was stronger than that between NO score and logMAR visual acuity or between NC score and logMAR visual acuity. CONCLUSION: Lens density as a quantitative and objective parameter can present the degree of NO and associated visual impairment due to nuclear cataract. The LOCS III criterion as an economic cataract grading system provides data that are in satisfactory concordance with the results obtained using the Pentacam Scheimpflug system.
机译:目的:调查使用Pentacam Scheimpflug系统测量的晶状体密度与使用透镜不透明度分类系统(LOCS)III的评分得分之间的关​​系,以及年龄相关性核白内障患者的晶状体密度与视敏度之间的关系。方法:对138例(180只眼)年龄相关性核性白内障患者的晶状体密度和分级评分进行了评估。用早期糖尿病视网膜病变研究图表测试LogMAR视力。分析了晶状体密度值与LOCS III核不透明度(NO)和核色(NC)等级评分之间的相关性,以及晶状体密度值与logMAR视敏度之间的相关性。结果:核白内障患者晶状体密度值与LOCS III评分之间呈线性增加的关系。镜头密度值与LOCS III NO得分的相关性强于NC得分。核晶状体密度值与logMAR视力之间的相关性强于NO得分与logMAR视力之间或NC得分与logMAR视力之间的相关性。结论:晶状体密度作为定量和客观的参数可以显示NO的程度和核白内障引起的相关视力障碍。作为经济性白内障分级系统的LOCS III标准提供的数据与使用Pentacam Scheimpflug系统获得的结果令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号