Pattern electroretinogram and automated perimetry in patients with glaucoma and ocular hypertension.

机译:青光眼和高眼压患者的模式视网膜电图和自动视野检查。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

To determine whether the pattern electroretinogram can improve the objectivity of visual field assessment, 39 patients with glaucoma and ocular hypertension were studied. This was to establish whether there is a correlation between the pattern electroretinogram and the global indices (mean deviation and corrected pattern standard deviation) provided by automated perimetry using the Humphrey visual field analyser. A significant correlation was found between the amplitude of the P50 + N95 wave of the pattern electroretinogram and the mean deviation and corrected pattern standard deviation components of the visual field. The larger the deviation from normal of these indices, particularly the corrected pattern standard deviation, the smaller the amplitude of the pattern electroretinogram. This correlation between the pattern electroretinogram and visual field indices provides an additional measure of confidence when interpreting equivocal results of automated perimetry.
机译:为了确定视网膜电图是否可以改善视野评估的客观性,对39例青光眼和高眼压患者进行了研究。这是为了确定图案视网膜电图与使用Humphrey视野分析仪通过自动视野检查提供的整体指标(均值偏差和校正后的图案标准偏差)之间是否存在相关性。发现图案视网膜电图的P50 + N95波的振幅与视野的平均偏差和校正后的图案标准偏差分量之间存在显着相关性。这些指标与法线的偏差越大,尤其是校正后的图案标准偏差越大,图案视网膜电图的振幅越小。当解释自动视野检查的模棱两可的结果时,图案视网膜电图和视野指数之间的这种相关性提供了一种额外的置信度度量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号