首页> 美国卫生研究院文献>The Journal of Physiology >Change of statistical parameters of transmitter release during various kinetic tests in unparalysed voltage-clamped rat diaphragm.
【2h】

Change of statistical parameters of transmitter release during various kinetic tests in unparalysed voltage-clamped rat diaphragm.

机译:在未瘫痪的电压钳制大鼠隔膜的各种动力学测试中变送器释放的统计参数的变化。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

1. The statistical nature of transmitter release was studied in unparalysed cut rat diaphragm using a voltage clamp technique at room temperature (23 degrees C). 2. While the binomial distribution described observed amplitude histograms well, the Poisson distribution was clearly inadequate. Values of m ranged from 40 to 45, while values for n varied from 45 to 53 and p was between 0.82 and 0.90. 3. Estimation of the probability of release from the transient decay of e.p.c.s in short tetanic trains (11 pulses, 150 Hz) gave values of p from 0.031 to 0.054, which are more than one order of magnitude lower than statistical estimates. 4. As a result of the short tetanic stimulation (5 pulses, 20, 50 and 100 Hz) there is an initial transient facilitation which afterwards becomes masked by depression. Statistical analysis suggests that the changes in the average numbers of quanta released (m) could be attributed to the change in the immediately available store (n). 5. During long tetanic stimulation (4000 pulses, 10-100 Hz) statistical analysis suggests that the decrease in the average number of quanta released (m) could be attributed almost entirely to the decrease in the immediately available store (n). The probability of release (p) decreased only slightly. The extent of the post-tetanic potentiation indicates that it cannot be explained on the grounds of increased probability of release (p) only. There should be an increase as well in the immediately available store (n). 6. It is suggested that while depression is most likely caused by the depletion of the immediately available store due to insufficient replenishment, the facilitation is probably caused by the increase in the capacity of the immediately available store to contain transmitter.
机译:1.在室温(23摄氏度)下使用电压钳技术在无瘫痪的大鼠隔膜中研究了变送器释放的统计性质。 2.虽然二项分布很好地描述了观察到的振幅直方图,但泊松分布显然不足。 m的值在40到45之间,而n的值在45到53之间变化,p在0.82到0.90之间。 3.在短的强壮性列车(11个脉冲,150 Hz)中,从e.p.c.s的瞬时衰减释放的可能性的估计得出p值从0.031到0.054,比统计估计值低​​一个数量级。 4.短暂的强直性刺激(5个脉冲,20、50和100 Hz)的结果是初始的短暂促进,其后被抑郁掩盖了。统计分析表明,释放的平均数量(m)的变化可以归因于立即可用商店(n)中的变化。 5.在长时间的强直性刺激(4000脉冲,10-100 Hz)中,统计分析表明,释放的平均量子数量(m)的减少几乎可以完全归因于立即可用存储区(n)的减少。释放的概率(p)仅略有下降。破伤风后增强作用的程度表明,不能仅以增加的释放概率(p)为理由对其进行解释。即时可用商店(n)也应增加。 6.建议虽然由于补给不足而使立即可用的商店枯竭最有可能造成沮丧,但促进作用可能是由于立即可用的商店容纳变送器的能力增加所致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号