Comparison of estimates of left ventricular ejection fraction obtained from gated blood pool imaging different software packages and cameras

机译:从门控血池成像不同软件包和相机获得的左心室射血分数估计值的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Serial measurement of LVEF using gated blood pool (GBP) imaging is an established technique for monitoring LVEF in patients undergoing chemotherapy with cardiotoxic medication and in patients after heart transplants.1, The nuclear medicine department at Groote Schuur Hospital performs up to a thousand GBP studies annually. The majority of these studies are for patients receiving cardiotoxic chemotherapy and have a significant impact on patient management.In our hospital, the radiation oncologists consider not starting cardiotoxic chemotherapy if the LVEF is below 50% and terminating chemotherapy if there is a 10% decrease. In patients who have had heart transplants, the cardiologists start patients on glucocorticosteroids if a patient’s LVEF decreases by10%. It is therefore imperative that serial studies on an individual patient are comparable.Two software systems are used in our nuclear medicine department. The Siemens system (Siemens Medical Solutions, Chicago, USA) was introduced in February 2006 and the Hermes system (Hermes Medical Solutions, Stockholm Sweden) in September 2007. After the introduction of the Hermes system, we found large differences between the LVEFs calculated by the two systems. This was confirmed by a pilot study and is consistent with the literature that different software programs for processing equilibrium gated radionuclide studies cannot be used interchangeably.-The department also uses two different cameras, a General Electric (GE) Starcam 400 AC single-head and a Siemens Signature Series e.cam dual-head camera to acquire the raw data. These are then transferred to the Siemens and Hermes processing systems.This study was done to determine how the software packages used for processing GBP studies should be integrated into our department and if the use of different cameras for acquisition influences results. The study had two components. The first examined the values and reproducibility of estimates of LVEF from two software packages using data acquired on the GE gamma camera and processed independently by three operators. The second component examined the values and reproducibility of estimates of LVEF calculated with the same software packages using matched pairs of raw data acquired on both gamma cameras (GE and Siemens) processed by one operator.
机译:使用门禁血池(GBP)成像对LVEF进行连续测量是一项用于监测接受心脏毒性药物化疗的患者和心脏移植后患者LVEF的既定技术。1,Groote Schuur医院核医学科进行了多达一千个GBP研究每年。这些研究中的大多数是针对接受心脏毒性化疗的患者,并且对患者管理产生重大影响。在我们医院,放射肿瘤学家考虑如果LVEF低于50%,则不开始心脏毒性化疗,如果LVEF降低10%,则终止化疗。对于进行过心脏移植的患者,如果患者的LVEF降低10%,则心脏病医生会开始使用糖皮质激素治疗。因此,必须对单个患者进行系列研究才能比较。我们的核医学科使用了两个软件系统。西门子系统(西门子医疗解决方案,美国芝加哥)于2006年2月推出,而爱马仕系统(赫尔姆斯医疗解决方案,瑞典斯德哥尔摩)于2007年9月推出。在引入爱马仕系统之后,我们发现通过这两个系统。一项初步研究证实了这一点,并且与文献相一致,处理平衡门控放射性核素研究的不同软件程序不能互换使用。-该部门还使用两个不同的摄像机,通用电气(GE)Starcam 400 AC单头和西门子Signature系列e.cam双头相机来获取原始数据。然后将它们传输到Siemens和Hermes处理系统。完成本研究的目的是确定用于处理GBP研究的软件包应如何集成到我们部门中,以及是否使用不同的摄像机进行采集是否会影响结果。该研究包括两个部分。第一个研究人员使用在GE伽玛相机上采集的数据并由三名操作员独立处理的数据,检查了来自两个软件包的LVEF估计值的值和可重复性。第二个组件检查了使用同一软件包计算的LVEF估计值的值和可重复性,其中使用了一对操作员在两台伽玛相机(GE和Siemens)上采集的原始数据的匹配对。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号