CAPD catheter malfunction is a common problem. Obstruction due to wrapping by appendices epiploicae of sigmoid colon has been rarely reported in literature. We report a case of CAPD catheter malfunction caused by catheter tip migration and obstruction by appendices epiploicae that was successfully managed by laparoscopic hanging loop technique. This case report highlights the ease with which epiplopexy can be performed and catheter tip migration can be prevented by this innovative laparoscopic procedure.
机译:CAPD导管故障是一个普遍的问题。乙状结肠的附件表皮包裹引起的阻塞在文献中很少报道。我们报告一例由腹腔镜吊环技术成功处理的由附件尖端引起的导管尖端迁移和阻塞引起的CAPD导管故障。该病例报告强调了通过这种创新的腹腔镜手术可以容易地进行癫痫发作并可以防止导管尖端迁移。