首页> 美国卫生研究院文献>Case Reports in Radiology >Catheter Fracture and Embolization Related to an Arm Venous Port
【2h】

Catheter Fracture and Embolization Related to an Arm Venous Port

机译:与手臂静脉口相关的导管破裂和栓塞

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This 55-year-old female had a chest X-ray during a follow-up visit for the management of her breast cancer. The chest X-ray demonstrated an embolized venous catheter superimposed upon the mediastinum. It was determined that the catheter of the patient's arm port had fractured and embolized to the pulmonary circulation. The catheter was retrieved, in the interventional radiology suite, under fluoroscopic guidance. The patient suffered no ill effects. Subsequently, one day later, the old vein port was removed and a new arm port and associated catheter were implanted to facilitate the delivery of the patient's ongoing chemotherapy.
机译:这位55岁的女性在随访过程中接受了胸部X光检查,以控制乳腺癌。胸部X光检查显示有栓塞的静脉导管叠加在纵隔上。确定患者手臂端口的导管已破裂并栓塞到肺循环中。在介入放射学套件中,在荧光镜引导下取回导管。病人没有任何不适。随后,一天后,移除了旧的静脉端口,并植入了新的手臂端口和相关的导管,以利于患者正在进行的化疗。