>Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the results of this method with those of radioimmunoassay ( RIA) [immunoradiometric (IRMA) for TSH] and Elisa. > Methods: Fasting serum from 112 hypo, hyper and euthyroid patients were used to evaluate the minimum detectable concentration, intra- and inter-assay precisions for TSH, FT4, T3, linearity for TSH assay and method comparison study. >Results: Within the analytical range tested, intra-assay coefficient of variation was < 2.3% for TSH, 2.3% for FT4 and 7.8% for T3. The inter-assay coefficient of variation was < 2.9% for TSH, 2.5% for FT4 and 12.3% for T3. The measurement of diluted sera indicated a desirable percentage of recovery for TSH. No correlation was found between Elecsys 2010 and Elisa /IRMA for TSH. The comparison of results of the Elecsys ECLIA assay with those of Elisa and RIA for T4 were: T4 (ECLIA) = -0.612+0.999, T4 (Elisa, r= 0.88) and T4 (ECLIA)=0.642+0.942 T4 (RIA, r=0.957), while ECLIA assay with Elisa and RIA for T3 were: T3 (ECLIA)= 0.242+0.908 T3 (Elisa, r=0.8) and T3 (ECLIA) = -0.029+1.01 T3 (RIA, r=0.957). >Conclusion: The results show that Elecsys 2010 is an automated reliable, efficient and technically excellent instrument to use in the measurement of serum TSH, T4 and T3.
机译:>背景:自从首次放射免疫测定法问世以来,免疫测定法的设计有了一些改进,例如抗体的生产方法,标记,自动化和检测技术。我们对Elecsys 2010免疫测定系统中血清TSH,FT4和T3的新化学发光免疫测定(ECLIA)进行了分析评估,并将该方法的结果与放射免疫测定(RIA)[TSH免疫放射测定(IRMA)]和Elisa进行了比较。 >方法:使用来自112名低,高和正常甲状腺患者的空腹血清评估TSH,FT4,T3的最低可检测浓度,测定内和测定间的精密度,TSH测定的线性和方法比较研究。 >结果:在测试的分析范围内,TSH的批内变异系数<2.3%,FT4的变异系数为2.3%,T3的变异系数为7.8%。对于TSH,测定间变异系数为<2.9%,对于FT4为<2.5%,对于T3为<12.3%。稀释血清的测定表明TSH的回收率理想。在Elecsys 2010和Elisa / IRMA之间没有发现TSH相关性。 Elecsys ECLIA分析与Elisa和RIA的T4结果的比较为:T4(ECLIA)= -0.612 + 0.999,T4(Elisa,r = 0.88)和T4(ECLIA)= 0.642 + 0.942 T4(RIA, r = 0.957),而使用Elisa和RIA进行的T3的ECLIA测定为:T3(ECLIA)= 0.242 + 0.908 T3(Elisa,r = 0.8)和T3(ECLIA)= -0.029 + 1.01 T3(RIA,r = 0.957) 。 >结论:结果表明,Elecsys 2010是一种自动化,可靠,高效且技术上非常出色的仪器,可用于测量血清TSH,T4和T3。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号