Competitive method-based electrochemiluminescent assay with protein–nucleotide conversion for ratio detection to efficiently monitor the drug resistance of cancer cells

机译:基于竞争性方法的蛋白质-核苷酸转换电化学发光测定法用于比率检测可有效监测癌细胞的耐药性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A simple and highly-efficient approach to monitor the expression of P-glycoprotein (P-gp) in cells was urgently needed to demonstrate the drug resistance of cancer cells. Herein, a competitive method-based electrochemiluminescent (ECL) assay with a single ECL indicator was proposed for the first time to efficiently estimate the concentration ratio of two proteins. By converting the different proteins to partially coincident nucleotide sequences via a sandwich type immunoassay on magnetic beads, the concentration ratio related ECL signals could be obtained via competitive nucleotide hybridization on an electrode surface. This method could thoroughly overcome the limitations of simultaneous ECL assays via multiple ECL indicators with inevitable cross reactions. At the same time, rolling circle amplification was employed to improve the detection performances, especially the detection limit and sensitivity. With P-gp and glyceraldehyde 3-phosphate dehydrogenase (GAPDH) as a model, the proposed ECL assay was successfully employed to monitor the drug resistance of cancer cells. Compared with conventional technologies, improved sensitivity and accuracy were achieved with a correlation coefficient of 0.9928 and a detection limit of 0.52%. Success in the establishment of the competitive method-based ECL assay offered an efficient strategy to demonstrate the concentration ratio of two proteins and a potential approach for detecting other proteins and nucleotide sequences, revealing a new avenue for ultrasensitive biomolecule diagnostics, especially in cell function research.
机译:迫切需要一种简单高效的方法来监测细胞中P-糖蛋白(P-gp)的表达,以证明癌细胞的耐药性。在本文中,首次提出了一种基于竞争性方法的电化学发光(ECL)测定法,该测定法具有单个ECL指示剂,以有效估计两种蛋白质的浓度比。通过在磁珠上通过夹心式免疫测定将不同的蛋白质转换为部分重合的核苷酸序列,可以通过在电极表面上进行竞争性核苷酸杂交获得与浓度比相关的ECL信号。这种方法可以通过多个ECL指标彻底避免同时进行ECL测定的局限性,并不可避免地发生交叉反应。同时,采用滚环放大技术提高检测性能,特别是检测限和灵敏度。以P-gp和3-磷酸甘油醛脱氢酶(GAPDH)为模型,所提出的ECL分析已成功用于监测癌细胞的耐药性。与传统技术相比,相关系数为0.9928,检出限为0.52%,从而提高了灵敏度和准确性。基于竞争性方法的ECL分析方法的成功建立提供了一种有效的策略来证明两种蛋白质的浓度比,并为检测其他蛋白质和核苷酸序列提供了一种可能的方法,这为超灵敏生物分子诊断(尤其是细胞功能研究)提供了新途径。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号