The purpose of this study was to investigate if a novel parameter, the stress-to-rest ratio of the signal-to-noise ratio (RSNR) obtained with a cadmium zinc telluride (CZT) SPECT scanner, could be used to distinguish triple-vessel disease (TVD) patients. Methods. One hundred and two patients with suspected coronary artery disease were retrospectively involved. Each subject underwent a Tl-201 SPECT scan and subsequent coronary angiography. Subjects were separated into TVD (n = 41) and control (n = 61) groups based on coronary angiography results using 50% as the stenosis cutoff. The RSNR was calculated by dividing the stress signal-to-noise ratio (SNR) by the rest SNR. Summed scores were calculated using quantitative perfusion SPECT (QPS) for all subjects. Results. The RSNR in the TVD group was found to be significantly lower than that in the control group (0.83 ± 0.15 and 1.06 ± 0.17, resp.; P < 0.01). Receiver-operating characteristic (ROC) analysis showed that RSNR can detect TVD more accurately than the summed difference score with higher sensitivity (85% versus 68%), higher specificity (90% versus 72%), and higher accuracy (88% versus 71%). Conclusion. The RSNR may serve as a useful index to assist the diagnosis of TVD when a fully automatic quantification method is used in CZT-based SPECT studies.
机译:这项研究的目的是研究是否可以使用一种新的参数,即碲化镉锌(CZT)SPECT扫描仪获得的信噪比(RSNR)的应力/静止比,来区分三重血管疾病(TVD)患者。方法。回顾性分析102例疑似冠心病患者。每个受试者进行T1-201 SPECT扫描和随后的冠状动脉造影。根据冠状动脉造影结果将受试者分为TVD组(n = 41)和对照组(n = 61),使用50%作为狭窄截止值。通过将应力信噪比(SNR)除以其余SNR来计算RSNR。使用定量灌注SPECT(QPS)计算所有受试者的总成绩。结果。 TVD组的RSNR显着低于对照组(0.83±0.15和1.06±0.17,分别; P <0.01)。接收器工作特性(ROC)分析显示,RSNR可以比总和差值更准确地检测TVD,具有更高的灵敏度(85%对68%),更高的特异性(90%对72%)和更高的准确性(88%对71) %)。结论。当在基于CZT的SPECT研究中使用全自动量化方法时,RSNR可以用作帮助诊断TVD的有用指标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号