首页> 外文期刊>Circulation journal >Combined supine and prone myocardial perfusion single-photon emission computed tomography with a cadmium zinc telluride camera for detection of coronary artery disease
【24h】

Combined supine and prone myocardial perfusion single-photon emission computed tomography with a cadmium zinc telluride camera for detection of coronary artery disease

机译:组合仰卧和俯卧的心肌灌注单光子发射与镉锌碲化镉相机进行了检测,用于检测冠状动脉疾病

获取原文
获取原文并翻译 | 示例
       

摘要

Background: Myocardial perfusion SPECT (MPS) traditionally requires the patient to be in the supine position, but diaphragmatic attenuation of the inferior wall reduces test specificity. The aim of this study was to assess the feasibility of combined MPS in the supine and prone positions using a novel cadmium zinc telluride (CZT) camera. Methods and Results: A total of 276 consecutive patients with suspected/known coronary artery disease (CAD) who underwent single-day 99 mTc-tetrofosmin or 99 mTc-sestamibi stress/rest CZT SPECT, were enrolled in the study. Seventysix underwent coronary angiography. Five-minute scan in the supine (S) position and thereafter in the prone (P) position produced images that were visually interpreted to obtain summed stress (SSS) and rest (SRS) scores. A combined stress score (C-SSS) was calculated by grouping anterior perfusion defects observed during supine imaging with inferior half segments observed during prone imaging. The SSS for the supine, prone, and combined protocols were 9±8, 7±8, and 7±8, respectively (P0.0001). The SRS were 5±8, 4±7, and 6±7, respectively (P=0.005). The area under the ROC curve for the S-SSS, P-SSS, and C-SSS scores was 0.815 (95% CI: 0.713-0.917), 0.813 (0.711-0.914), and 0.872 (0.783-0.961), respectively. Corresponding sensitivities and specificities for detecting CAD were 87% and 50%, 80% and 77%, and 85% and 82%, respectively. C-SSS had significantly better specificity and accuracy than S-SSS (P0.05). Conclusions: Combined imaging with a CZT camera is suitable for routine clinical MPS and provides greater diagnostic accuracy than supine imaging alone.
机译:背景:心肌灌注SPECT(MPS)传统上要求患者处于仰卧位,但下壁的膜膜衰减降低了测试特异性。本研究的目的是利用新型镉锌碲化镉(CZT)相机来评估仰卧和俯卧位的合并MPS的可行性。方法和结果:共有276名可疑/已知的冠状动脉疾病(CAD)的患者(CAD),他们在研究中进行单日99 MTC-四孢子或99mTC-Sestamibi应激/静态SPECT。 Seventysix接受了冠状动脉造影。在仰卧位扫描仰卧位位置,然后在俯卧(P)位置产生目视解释的图像以获得总和应力(SSS)和休息(SRS)分数。通过在俯卧位成像期间观察到的仰卧成像期间观察到的前灌注缺陷来计算组合应力评分(C-SSS)。 SSS为仰卧,容易发生和组合方案分别为9±8,7±8和7±8(P <0.0001)。 SRS分别为5±8,4±7和6±7(P = 0.005)。 S-SSS,P-SSS和C-SSS分数下的ROC曲线下的区域分别为0.815(95%CI:0.713-0.917),0.813(0.711-0.914)和0.872(0.783-0.961)。检测CAD的相应敏感性和特异性分别为87%和50%,80%和77%,分别为85%和82%。 C-SSS具有比S-SSS更好的特异性和准确性(P <0.05)。结论:与CZT相机的合并成像适用于常规临床MPS,并提供比单独的仰卧成像更大的诊断精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号