首页> 美国卫生研究院文献>Sleep Disorders >Pulse Oximetry for the Detection of Obstructive Sleep Apnea Syndrome: Can the Memory Capacity of Oxygen Saturation Influence Their Diagnostic Accuracy?
【2h】

Pulse Oximetry for the Detection of Obstructive Sleep Apnea Syndrome: Can the Memory Capacity of Oxygen Saturation Influence Their Diagnostic Accuracy?

机译:脉搏血氧饱和度检测阻塞性睡眠呼吸暂停综合症:氧饱和度的记忆能力会影响其诊断准确性吗?

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective. To assess the diagnostic ability of WristOx 3100 using its three different recording settings in patients with suspected obstructive sleep apnea syndrome (OSAS). Methods. All participants (135) performed the oximetry (three oximeters WristOx 3100) and polysomnography (PSG) simultaneously in the sleep laboratory. Both recordings were interpreted blindly. Each oximeter was set to one of three different recording settings (memory capabilities 0.25, 0.5, and 1 Hz). The software (nVision 5.1) calculated the adjusted O2 desaturation index-mean number of O2 desaturation per hour of analyzed recording ≥2, 3, and 4% (ADI2, 3, and 4). The ADI2, 3, and 4 cutoff points that better discriminated between subjects with or without OSAS arose from the receiver-operator characteristics (ROCs) curve analysis. OSAS was defined as a respiratory disturbance index (RDI) ≥ 5. Results. 101 patients were included (77 men, mean age 52, median RDI 22.6, median BMI 27.4 kg/m2). The area under the ROCs curves (AUC-ROCs) of ADI2, 3, and 4 with different data storage rates were similar (AUC-ROCs with data storage rates of 0.25/0.5/1 Hz: ADI2: 0.958/0.948/0.965, ADI3: 0.961/0.95/0.966, and ADI4: 0.957/0.949/0.963, P NS). Conclusions. The ability of WristOx 3100 to detect patients with OSAS was not affected by the data storage rate of the oxygen saturation signal. Both memory capacity of 0.25, 0.5, or 1 Hz showed a similar performance for the diagnosis of OSAS.
机译:目的。使用三种不同的记录设置来评估WristOx 3100在可疑阻塞性睡眠呼吸暂停综合症(OSAS)患者中的诊断能力。方法。所有参与者(135)在睡眠实验室中同时进行了血氧测定法(三个血氧计WristOx 3100)和多导睡眠图(PSG)。两种录音都是盲目解释的。每个血氧仪都设置为三种不同的记录设置之一(存储能力0.25、0.5和1 Hz)。该软件(nVision 5.1)计算了调整后的O2脱饱和指数-每小时分析的记录中≥2%,3%和4%(ADI2、3和4)的O2脱饱和数。接收者-操作者特征(ROC)曲线分析可以更好地区分带有或不带有OSAS的受试者的ADI2、3和4截止点。 OSAS被定义为呼吸干扰指数(RDI)≥5。结果。纳入101例患者(77名男性,平均年龄52岁,中位RDI 22.6,中位BMI 27.4 kg / m 2 )。数据存储速率不同的ADI2、3和4的ROC曲线下面积(AUC-ROC)相似(数据存储速率为0.25 / 0.5 / 1 Hz的AUC-ROC:ADI2:0.958 / 0.948 / 0.965,ADI3 :0.961 / 0.95 / 0.966和ADI4:0.957 / 0.949 / 0.963,PNS)。结论。 WristOx 3100检测OSAS患者的能力不受氧饱和度信号的数据存储速率的影响。 0.25、0.5或1 Hz的两种存储容量在诊断OSAS方面表现出相似的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号