首页> 美国卫生研究院文献>The Scientific World Journal >Reliability of a Novel CBCT-Based 3D Classification System for Maxillary Canine Impactions in Orthodontics: The KPG Index
【2h】

Reliability of a Novel CBCT-Based 3D Classification System for Maxillary Canine Impactions in Orthodontics: The KPG Index

机译:新型基于CBCT的正畸上颌犬撞击3D分类系统的可靠性:KPG指数

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of this study was to evaluate both intra- and interoperator reliability of a radiological three-dimensional classification system (KPG index) for the assessment of degree of difficulty for orthodontic treatment of maxillary canine impactions. Cone beam computed tomography (CBCT) scans of fifty impacted canines, obtained using three different scanners (NewTom, Kodak, and Planmeca), were classified using the KPG index by three independent orthodontists. Measurements were repeated one month later. Based on these two sessions, several recommendations on KPG Index scoring were elaborated. After a joint calibration session, these recommendations were explained to nine orthodontists and the two measurement sessions were repeated. There was a moderate intrarater agreement in the precalibration measurement sessions. After the calibration session, both intra- and interrater agreement were almost perfect. Indexes assessed with Kodak Dental Imaging 3D module software showed a better reliability in z-axis values, whereas indexes assessed with Planmeca Romexis software showed a better reliability in x- and y-axis values. No differences were found between the CBCT scanners used. Taken together, these findings indicate that the application of the instructions elaborated during this study improved KPG index reliability, which was nevertheless variously influenced by the use of different software for images evaluation.
机译:这项研究的目的是评估放射三维分类系统(KPG指数)的术中和术中可靠性,以评估正畸治疗上颌尖牙的影响的难度。使用三个不同的扫描仪(NewTom,Kodak和Planmeca)获得的五十个受累犬的锥形束计算机断层扫描(CBCT)扫描由三位独立的正畸医生使用KPG索引进行分类。一个月后重复测量。在这两届会议的基础上,提出了一些有关KPG指数评分的建议。在联合校准会议之后,向九位正畸医生解释了这些建议,并重复了两次测量会议。在预校准测量会议中达成了中等评估者内部协议。校准会议结束后,内部和内部协议几乎都是完美的。使用Kodak Dental Imaging 3D模块软件评估的索引在z轴值上显示出更好的可靠性,而使用Planmeca Romexis软件评估的索引在x轴和y轴上显示出更好的可靠性。使用的CBCT扫描仪之间未发现差异。综上所述,这些发现表明,在这项研究中详细阐述的说明的应用提高了KPG指数的可靠性,但是,使用不同的软件进行图像评估对KPG指数的可靠性产生了各种影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号