摘要

The paper focuses on the analysis and detection of electroactive compounds using high-performance liquid chromatography (HPLC) combined with electrochemical detection (EC). The fabrication and utilization of electrochemically treated carbon fiber microelectrodes (CFMs) as highly sensitive amperometric detectors in HPLC are described. The applied pretreatment procedure is beneficial for analytical characteristics of the sensor as demonstrated by analysis of the model set of phenolic acids. The combination of CFM with separation power of HPLC technique allows for improved detection limits due to unique electrochemical properties of carbon fibers. The CFM proved to be a promising tool for amperometric detection in liquid chromatography.
机译:本文着重于结合高效液相色谱(HPLC)和电化学检测(EC)进行电活性化合物的分析和检测。描述了电化学处理的碳纤维微电极(CFM)作为HPLC中的高灵敏度安培检测器的制造和利用。通过对酚酸模型集的分析证明,所应用的预处理程序对于传感器的分析特性是有益的。 CFM与HPLC技术的分离能力相结合,由于碳纤维具有独特的电化学性能,因此可以提高检测限。 CFM被证明是液相色谱中用于安培检测的有前途的工具。