首页> 美国卫生研究院文献>Revista Brasileira de Ortopedia >Recovery of the Hip Rotation Center with Tantalum in Revision Arthroplasty
【2h】

Recovery of the Hip Rotation Center with Tantalum in Revision Arthroplasty

机译:关节置换术中用钽修复髋关节旋转中心

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Objective  The objective of the present study is to evaluate the restoration capacity of the hip anatomic rotation center with the use of acetabular tantalum cups, associated or not with addition wedges. >Methods  Retrospective analysis of patients undergoing hip arthroplasty revision using tantalum between June 2013 and April 2017. The abduction angle of the acetabular component and the horizontal and vertical distances of the component to the center of anatomical rotation of the hip were evaluated. The measurements were made through baseline radiographs performed in the preoperative period and at the last follow-up visit. >Results  A sample of 21 patients was obtained, 11 (52%) men and 10 (48%) women, with a mean age of 62 ± 13 years old. The mean abduction angle of the acetabular cup decreased from 48.76° ± 13.88 ° in the preoperative period to 38.52° ± 10.08 ° in the postoperative period, and this difference was statistically significant ( p  = 0.001). The distances from the center of rotation of the prosthesis relative to the center of anatomical rotation of the hip were also lower after revision surgery with tantalum. The mean horizontal distance of 12.74 ± 10.59 mm was reduced to 7.11 ± 4.84 mm, and the mean vertical distance was reduced from 14.79 ± 10.05 mm to 4.89 ± 6.21 mm, and these reductions were statistically significant ( p  < 0.001). >Conclusion  Hip arthroplasty revision with tantalum cups, associated or not with addition wedges, significantly recovered the anatomical rotation center of the hip.
机译:>目的本研究的目的是评估髋臼解剖旋转中心在髋臼钽杯的使用情况下(无论是否与附加楔块结合)的恢复能力。 >方法回顾性分析2013年6月至2017年4月间使用钽进行髋关节置换术的患者。髋臼假体的外展角度以及该假体与髋关节解剖旋转中心之间的水平和垂直距离被评估。通过在术前和最后一次随访中进行的基线射线照相进行测量。 >结果获得了21例患者的样本,其中11例(52%)男性和10例(48%)女性,平均年龄为62±±13岁。髋臼杯的平均外展角从术前的48.76°±13.88°降低到术后的38.52°±10.08°,差异具有统计学意义(p = 0.001)。钽翻修手术后,假体旋转中心相对于髋部解剖旋转中心的距离也较小。平均水平距离从12.74±10.59mm减小到7.11±4.84mm,平均垂直距离从14.79±10.05mm减小到4.89±6.21mm,这些减少具有统计学意义(p <0.001)。 >结论带钽杯的髋关节置换术(无论是否与附加楔块结合)可显着恢复髋关节的解剖旋转中心。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号