首页> 美国卫生研究院文献>Oncotarget >Dosimetric impact of multileaf collimator leaf width according to sophisticated grade of technique in the IMRT and VMAT planning for pituitary adenoma lesion
【2h】

Dosimetric impact of multileaf collimator leaf width according to sophisticated grade of technique in the IMRT and VMAT planning for pituitary adenoma lesion

机译:根据IMRT和VMAT规划中垂体腺瘤病变的复杂技术等级对多叶准直器叶片宽度进行剂量学影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We analyzed the difference in the dosimetric effect between 5-mm and 2.5-mm multileaf collimator (MLC) leaf width according to the sophisticated grades of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). Nineteen patients with pituitary adenomas were selected for this study. The treatment plans were performed according to the size of the MLC (5-mm and 2.5-mm MLC), the type of technique (IMRT and VMAT), and the sophisticated grades of each technique (5-field, 9-field, 13-field, 17-field technique in IMRT and 1-arc and 2-arc techniques in VMAT). The downsizing effects of MLC leaf width were analyzed using target volume coverage (TVC), conformity index (CI), dose gradient index (GI), and normal tissue difference 70% isodose line and 50% isodose line. Upon replacing the 5-mm MLC with the 2.5-mm MLC, TVC and CI improved by 1.30% and 1.36%, respectively, in total plans. The TVC and CI improved by 1.68% and 1.67% in IMRT, respectively, and by 0.54% and 0.72% in VMAT, respectively. TVC improved by 2.53%, 1.82%, 1.34%, and 0.94%, and CI also improved by 2.70%, 1.81%, 1.24%, and 0.94%, in 5-field, 9-field, 13-field, and 17-field IMRT, respectively. TVC improved by 0.66% and 0.43%, and CI also improved by 0.93%, and 0.52% in 1-arc and 2-arc VMAT, respectively. Regarding the target coverage, there were dosimetric benefits of a smaller MLC leaf width. However, the downsizing effect of the MLC leaf width decreased with the use of a more precise RT technique and a more sophisticated grade of the same technique.
机译:我们根据强度调制放射疗法(IMRT)和体积调制弧光疗法(VMAT)的复杂等级,分析了5毫米和2.5毫米多叶准直器(MLC)叶宽之间的剂量学效应差异。本研究选择了19例垂体腺瘤患者。根据MLC的尺寸(5毫米和2.5毫米MLC),技术类型(IMRT和VMAT)以及每种技术的复杂等级(5场,9场,13场)执行治疗计划IMRT中的1场和17场技术以及VMAT中的1弧和2弧技术。使用目标体积覆盖率(TVC),合格指数(CI),剂量梯度指数(GI)和正常组织差异70%等剂量线和50%等剂量线分析了MLC叶宽的缩小效果。在将2.5毫米MLC替换为5毫米MLC时,TVC和CI的总体计划分别提高了1.30%和1.36%。 IMRT的TVC和CI分别提高了1.68%和1.67%,VMAT的TVC和CI分别提高了0.54%和0.72%。在5场,9场,13场和17场中,TVC分别提高了2.53%,1.82%,1.34%和0.94%,CI也分别提高了2.70%,1.81%,1.24%和0.94%。字段分别为IMRT。在1弧形和2弧形VMAT中,TVC分别提高了0.66%和0.43%,CI也分别提高了0.93%和0.52%。关于目标覆盖范围,MLC叶片宽度较小具有剂量优势。但是,通过使用更精确的RT技术和同一技术的更复杂等级,MLC叶片宽度的缩小效果降低了。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号