There is an immediate need for improved methods to systematically and precisely quantify large sets of peptides in complex biological samples. To date protein quantification in biological samples has been routinely performed on triple quadrupole instruments operated in selected reaction monitoring mode (SRM), and two major challenges remain. Firstly, the number of peptides to be included in one survey experiment needs to be increased to routinely reach several hundreds, and secondly, the degree of selectivity should be improved so as to reliably discriminate the targeted analytes from background interferences. High resolution and accurate mass (HR/AM) analysis on the recently developed Q-Exactive mass spectrometer can potentially address these issues. This instrument presents a unique configuration: it is constituted of an orbitrap mass analyzer equipped with a quadrupole mass filter as the front-end for precursor ion mass selection. This configuration enables new quantitative methods based on HR/AM measurements, including targeted analysis in MS mode (single ion monitoring) and in MS/MS mode (parallel reaction monitoring). The ability of the quadrupole to select a restricted m/z range allows one to overcome the dynamic range limitations associated with trapping devices, and the MS/MS mode provides an additional stage of selectivity. When applied to targeted protein quantification in urine samples and benchmarked with the reference SRM technique, the quadrupole-orbitrap instrument exhibits similar or better performance in terms of selectivity, dynamic range, and sensitivity. This high performance is further enhanced by leveraging the multiplexing capability of the instrument to design novel acquisition methods and apply them to large targeted proteomic studies for the first time, as demonstrated on 770 tryptic yeast peptides analyzed in one 60-min experiment. The increased quality of quadrupole-orbitrap data has the potential to improve existing protein quantification methods in complex samples and address the pressing demand of systems biology or biomarker evaluation studies.
机译:迫切需要改进的方法来系统地和精确地定量复杂生物样品中的大量肽。迄今为止,生物样品中的蛋白质定量通常是在以选定的反应监测模式(SRM)运行的三重四极杆仪器上进行的,仍然存在两个主要挑战。首先,一个调查实验中要包括的肽数量需要增加到常规的几百种,其次,应该提高选择性,以可靠地将目标分析物与背景干扰区分开。在最近开发的Q-Exactive质谱仪上进行高分辨率和精确质量(HR / AM)分析可以潜在地解决这些问题。该仪器具有独特的配置:它由Orbitrap质量分析仪组成,该分析仪配有四极质量过滤器,作为选择前体离子质量的前端。此配置启用了基于HR / AM测量的新定量方法,包括MS模式(单离子监测)和MS / MS模式(平行反应监测)的目标分析。四极杆选择受限m / z范围的能力使人们能够克服与捕集装置相关的动态范围限制,而MS / MS模式则提供了额外的选择性阶段。当应用于尿液样品中的目标蛋白质定量并通过参考SRM技术进行基准测试时,四极杆Orbitrap仪器在选择性,动态范围和灵敏度方面表现出相似或更好的性能。通过利用仪器的多路复用功能来设计新颖的采集方法并将其首次应用于大型目标蛋白质组学研究,进一步提高了这种高性能,正如在一个60分钟的实验中分析的770种胰蛋白酶酵母肽所证明的那样。四极轨道飞行器数据质量的提高有可能改善复杂样品中现有的蛋白质定量方法,并满足系统生物学或生物标志物评估研究的紧迫需求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号